Auswahlhilfe
PLD905-25W-P vs SPL PL90: two 25 W class 905 nm pulsed laser diodes
A datasheet comparison of PLD905-25W-P and SPL PL90 covering power definitions, emitter geometry, drive current, voltage, test conditions and substitution limits.
Aktualisiert 2026-11-16 · 3 Min. Lesezeit
PLD905-25W-P and OSRAM SPL PL90 are both 905 nm short-pulse emitters in plastic packages, but the shared 25 W class label does not make them interchangeable. Their emitter structures, geometry, electrical operating points and datasheet conditions differ.
PLD905-25W-P is marketed as a 25 W part, while its characteristic table lists 29 W typical and 32.8 W maximum. SPL PL90 lists 25 W typical and 30 W maximum. Values taken under different conditions cannot be treated as a same-condition performance comparison.
Product: PLD905-25W-P.
Key comparison
| Parameter | PLD905-25W-P | SPL PL90 |
|---|---|---|
| Wavelength | 905 nm, 895-915 nm | 905 nm, 895-915 nm |
| Spectral width | 7 nm FWHM typical | 7 nm FWHM typical |
| Power definition | 25 W name; table 23.9 min / 29 typ / 32.8 max | 20 min / 25 typ / 30 max |
| Emitter | 70 x 10 um | 200 x 2 um |
| Divergence FWHM | 9 x 25 degrees typical | 11 x 25 degrees |
| Threshold current | 0.75 A typical | 0.75 A typical |
| Operating current | 11 A, 9-13 A | 30 A |
| Operating voltage | 9.4 V, 8.8-10 V | 4.3 V, 3.3-5.3 V |
| Standard repetition | 3 kHz | 1 kHz |
| Maximum pulse width / duty | 100 ns / 0.1% | 100 ns / 0.1% |
| Wavelength drift | 0.28 nm/K | 0.28 nm/K |
Emitter geometry
PLD905-25W-P uses three epitaxial stacked emitters and a 70 x 10 um emitting area. SPL PL90 uses a large optical cavity and a roughly 200 um lateral aperture. Those descriptions cannot be ranked by name alone.
The geometric products are about 700 um2 and 400 um2, but this is not effective emitting area and does not determine the final target spot. Collimation, far-field distribution, distance and alignment also matter. Use the spot-at-distance calculator for a first estimate.
Driver differences
PLD905-25W-P operates near 11 A and 9.4 V typical; SPL PL90 operates near 30 A and 4.3 V. A common driver is therefore not assumed:
- PLD needs higher compliance voltage and lower current.
- SPL needs lower voltage and higher pulse current.
- Loop inductance, switch voltage rating, connector drop and pulse probe bandwidth must be rechecked.
- The 1 kHz and 3 kHz reference conditions must be harmonised before comparing power and heating.
The product of typical current and voltage is only a scale check, not an efficiency measurement. Use the peak-power and average-power calculators to connect pulse width, energy and repetition rate.
Application fit
PLD905-25W-P lists handheld ranging, golf, hunting, construction measurement, UAV ranging/obstacle sensing and professional laser sensors. SPL PL90 lists range finding, security, illumination/ignition and test and measurement.
Application descriptions do not certify a finished product. Start with the LiDAR link-budget calculator, then include receiver sensitivity, target reflectance and ambient light.
Replacement checks
- Clarify the 25 W name, 29 W typical value and guaranteed procurement range.
- Compare current mechanical drawings, pin polarity, lead frame and emitter position.
- Measure optical power under identical pulse width, repetition, temperature and current.
- Measure voltage, current, edges, overshoot and reverse spikes on the real driver.
- Validate both axes of the far field and the collimated target-plane spot.
- Test power drift and life across temperature and repetition rate.
- Re-run complete-product laser-safety classification.
Conclusion: wavelength, spectral width, threshold current and temperature range are similar, but electrical operating points, emitter geometry and application fit differ. The PLD power definition must be clarified and a same-condition A/B test is required before substitution.
Produkte
Verwandte Produkte
Kunststoff-Spritzgussgehäuse
PLD905-25W-P
905 nm, 25 W Spitzenleistung, nicht kollimiert
Rechner
Mit diesem Datenblatt rechnen
Jeder Rechner unten öffnet sich mit den Datenblattwerten dieses Bauteils bereits eingetragen, in den Einheiten, die die Felder verlangen.
Puls-Spitzenleistung
Momentane Spitzenleistung aus Pulsenergie und Pulsbreite.
Spitzenleistung 25 W · Pulsenergie 0.0025 mJ · Pulsbreite 100 ns Laser-GrundlagenTastgrad und thermische Last
Anteil der Einschaltzeit des Lasers aus Pulsbreite und Wiederholrate.
Tastgrad 0.1 % · Pulsbreite 100 ns · Wiederholrate 10 kHz Laser-GrundlagenMittlere Leistung
Kontinuierliche mittlere Leistung aus Wiederholrate und Energie pro Puls.
Energie pro Puls 0.0025 mJ · Wiederholrate 10 kHz Laser-GrundlagenFleckgröße bei Entfernung z
Strahlradius in einer Entfernung z von der Taille.
Entfernungsmessung & LiDARLiDAR-Linkbudget
Abschätzung der am Empfänger erfassten optischen Leistung.
Weiterführende Lektüre
785-nm-Multimode-homogenisierter-Faserlaser: gleichmäßige Beleuchtung, Totalstation-Optik und Validierungsgrenzen
Ein praktischer Leitfaden für einen 785-nm-, 90-mW-, 200/340-µm-homogenisierten-Faserlaser, der die Gleichmäßigkeit der Beleuchtung, Zusatzoptik für Totalstationen, Leistungsbudgetierung und Messung abdeckt.
Optik905 nm Raman DTS: Bericht über Ingenieurumsetzung und Validierung
Eine vollständige Ingenieurstrecke von einer 905 nm gepulsten Pumpe und etwa 870/943 nm Raman-Kanälen über duale APDs, synchrone Erfassung, Differenzverlusterkennung, Temperaturinversion, Kalibrierung und Prototypenvalidierung.
Auswahlhilfe905 nm, 1535 nm oder 1550 nm: die Wellenlänge für Entfernungsmessung und LiDAR wählen
Die Wahl der Wellenlänge bestimmt Detektor, Laserschutzklasse, nutzbare Energie und Wetterverhalten. So schneiden die drei Bänder bei der Entfernungsmessung tatsächlich ab.