PLD905-70W-M and OSRAM SPL TL90AT03 are both 905 nm TO56 metal-can lasers aimed at nanosecond pulse applications. The obvious difference is 70 W versus 65 W typical peak power, but voltage, emitter geometry and test conditions decide whether one can replace the other.
Product: PLD905-70W-M.
| Parameter | PLD905-70W-M | SPL TL90AT03 |
|---|---|---|
| Wavelength | 905 nm, 895-915 nm | 905 nm, 898-912 nm |
| Spectral width | 7 nm typical | 7 nm typical |
| Peak power | 70 W, 66-74 W table range | 65 W typical |
| Current | 20 A | 20 A |
| Standard repetition | 3 kHz | 1 kHz |
| Voltage | 15.6 V typical, 14.4-15.8 V | 9.5 V typical |
| Threshold current | 0.75 A typical | 0.3 A typical |
| Emitter | 90 x 18 um | 110 x 10 um |
| Divergence FWHM | 9 x 25 degrees | 10 x 25 degrees |
| Wavelength drift | 0.28 nm/K | Not listed |
| Maximum pulse width / duty | 100 ns / 0.1% | 100 ns / 0.1% |
The 5 W difference is about 7.7% of the 65 W value, but the standard repetition rates differ and the parts use different structures and operating points. It is not a same-condition measurement.
Driver and electrical checks
PLD905-70W-M needs significantly more compliance voltage. Before substitution, verify supply headroom, switch ratings, transformer design, loop inductance and reverse-spike protection. SPL TL90AT03 must also be operated within its own limits rather than the PLD limits.
Measure current, pulse width, edges, overshoot, reverse spikes, repetition, case temperature and sample-to-sample variation on the real board. Use the peak-power, duty-cycle and average-power calculators to check the electrical and thermal operating point.
Optical checks
The 90 x 18 um and 110 x 10 um emitters produce different near-field geometry and different fast/slow-axis collimation requirements. The FWHM divergence is only an input to the optical design, not the target spot size.
Measure the complete far field, collimator NA, alignment tolerance and target-plane spot. The spot-at-distance calculator provides a first footprint estimate.
Application boundaries
PLD905-70W-M can be evaluated for handheld ranging, golf, hunting, construction, UAV sensing and industrial distance measurement. SPL TL90AT03 also lists 3D sensing, gesture recognition, security and machine-control applications.
Neither datasheet makes the bare laser a certified finished product. The OSRAM document states that the component is not released for automotive use or developed as a safety- or medical-grade device. Missing qualification data for the other part must not be read as certification.
Use the LiDAR link-budget calculator when comparing complete ranging architectures.
Replacement sequence
- Confirm PLD905-70W-M suffix, pin option and package drawing.
- Compare driver voltage, current and pulse waveform.
- Measure optical power under identical pulse, repetition, temperature and current.
- Compare near field, far field and target-plane spot.
- Test low- and high-temperature power and wavelength drift.
- Recheck reverse-spike protection and complete-product eye safety.
Conclusion: 70 W versus 65 W is only the starting point. PLD905-70W-M is suitable for evaluation where the driver has enough voltage headroom and the PLD package is appropriate. OSRAM SPL TL90AT03 requires its own lower-voltage, three-emitter thermal design. A same-condition A/B test is mandatory before replacement.
Ürünler
İlgili ürünler
TO56 kılıf
PLD905-70W-M
905 nm, 70 W tepe, kolimasyonsuz
Hesaplayıcılar
Bu veri sayfasıyla hesaplayın
Aşağıdaki her hesaplayıcı, bu parçanın veri sayfası değerleri alanların istediği birimlerde önceden doldurulmuş olarak açılır.
Darbe Tepe Gücü
Mühendislik hesaplayıcısı: darbe tepe gücü hesaplar ve girdilerin sonuç üzerindeki etkisini değerlendirir.
Tepe güç 70 W · Darbe enerjisi 0.007 mJ · Darbe genişliği 100 ns Lazer TemelleriGörev Döngüsü ve Isıl Yük
Mühendislik hesaplayıcısı: görev döngüsü ve isıl yük hesaplar ve girdilerin sonuç üzerindeki etkisini değerlendirir.
Görev döngüsü 0.1 % · Darbe genişliği 100 ns · Tekrar hızı 10 kHz Lazer TemelleriOrtalama Güç
Mühendislik hesaplayıcısı: ortalama güç hesaplar ve girdilerin sonuç üzerindeki etkisini değerlendirir.
Darbe başına enerji 0.007 mJ · Tekrar hızı 10 kHz Lazer Temelleriz Mesafesindeki Nokta Boyutu
Mühendislik hesaplayıcısı: z mesafesindeki nokta boyutu hesaplar ve girdilerin sonuç üzerindeki etkisini değerlendirir.
Mesafe Ölçümü ve LiDARLiDAR Bağlantı Bütçesi
Mühendislik hesaplayıcısı: lidar bağlantı bütçesi hesaplar ve girdilerin sonuç üzerindeki etkisini değerlendirir.
İlgili okumalar
785 nm multimod homogenize-fiber lazer: uniform aydınlatma, total-station optiği ve doğrulama limitleri
Aydınlatma uniformluğunu, total-station yardımcı optiğini, güç bütçelemesini ve ölçümü kapsayan 785 nm, 90 mW, 200/340 um homogenize-fiber lazere pratik bir rehber.
Optik905 nm Raman DTS: mühendislik uygulama ve doğrulama raporu
905 nm darbeli pompa ve yaklaşık 870/943 nm Raman kanalları üzerinden çift APD, eşzamanlı edinim, diferansiyel kayıp düzeltmesi, sıcaklık ters çevirme, kalibrasyon ve prototip doğrulaması içeren eksiksiz bir mühendislik yolu.
Seçim kılavuzu905 nm, 1535 nm ve 1550 nm: mesafe ölçümü ve LiDAR için dalga boyu seçimi
Dalga boyu kararı dedektörünüzü, göz güvenliği sınıfınızı, kullanabileceğiniz en yüksek enerjiyi ve hava koşullarındaki performansınızı belirler. Üç bandın mesafe ölçümünde gerçekte nasıl karşılaştığını açıklıyoruz.