دليل الاختيار
PLD905-70W-M vs OSRAM SPL TL90AT03: 70 W and 65 W 905 nm lasers
A datasheet comparison of PLD905-70W-M and OSRAM SPL TL90AT03 covering peak power, voltage, emitter geometry, thermal data, applications and replacement validation.
حُدِّث 2026-11-16 · 3 دقائق قراءة
PLD905-70W-M and OSRAM SPL TL90AT03 are both 905 nm TO56 metal-can lasers aimed at nanosecond pulse applications. The obvious difference is 70 W versus 65 W typical peak power, but voltage, emitter geometry and test conditions decide whether one can replace the other.
Product: PLD905-70W-M.
| Parameter | PLD905-70W-M | SPL TL90AT03 |
|---|---|---|
| Wavelength | 905 nm, 895-915 nm | 905 nm, 898-912 nm |
| Spectral width | 7 nm typical | 7 nm typical |
| Peak power | 70 W, 66-74 W table range | 65 W typical |
| Current | 20 A | 20 A |
| Standard repetition | 3 kHz | 1 kHz |
| Voltage | 15.6 V typical, 14.4-15.8 V | 9.5 V typical |
| Threshold current | 0.75 A typical | 0.3 A typical |
| Emitter | 90 x 18 um | 110 x 10 um |
| Divergence FWHM | 9 x 25 degrees | 10 x 25 degrees |
| Wavelength drift | 0.28 nm/K | Not listed |
| Maximum pulse width / duty | 100 ns / 0.1% | 100 ns / 0.1% |
The 5 W difference is about 7.7% of the 65 W value, but the standard repetition rates differ and the parts use different structures and operating points. It is not a same-condition measurement.
Driver and electrical checks
PLD905-70W-M needs significantly more compliance voltage. Before substitution, verify supply headroom, switch ratings, transformer design, loop inductance and reverse-spike protection. SPL TL90AT03 must also be operated within its own limits rather than the PLD limits.
Measure current, pulse width, edges, overshoot, reverse spikes, repetition, case temperature and sample-to-sample variation on the real board. Use the peak-power, duty-cycle and average-power calculators to check the electrical and thermal operating point.
Optical checks
The 90 x 18 um and 110 x 10 um emitters produce different near-field geometry and different fast/slow-axis collimation requirements. The FWHM divergence is only an input to the optical design, not the target spot size.
Measure the complete far field, collimator NA, alignment tolerance and target-plane spot. The spot-at-distance calculator provides a first footprint estimate.
Application boundaries
PLD905-70W-M can be evaluated for handheld ranging, golf, hunting, construction, UAV sensing and industrial distance measurement. SPL TL90AT03 also lists 3D sensing, gesture recognition, security and machine-control applications.
Neither datasheet makes the bare laser a certified finished product. The OSRAM document states that the component is not released for automotive use or developed as a safety- or medical-grade device. Missing qualification data for the other part must not be read as certification.
Use the LiDAR link-budget calculator when comparing complete ranging architectures.
Replacement sequence
- Confirm PLD905-70W-M suffix, pin option and package drawing.
- Compare driver voltage, current and pulse waveform.
- Measure optical power under identical pulse, repetition, temperature and current.
- Compare near field, far field and target-plane spot.
- Test low- and high-temperature power and wavelength drift.
- Recheck reverse-spike protection and complete-product eye safety.
Conclusion: 70 W versus 65 W is only the starting point. PLD905-70W-M is suitable for evaluation where the driver has enough voltage headroom and the PLD package is appropriate. OSRAM SPL TL90AT03 requires its own lower-voltage, three-emitter thermal design. A same-condition A/B test is mandatory before replacement.
المنتجات
منتجات ذات صلة
عبوة TO56
الحاسبات
احسب بصحيفة البيانات هذه
كل حاسبة أدناه تُفتح وقيم صحيفة بيانات هذه القطعة معبَّأة مسبقًا، بالوحدات التي تطلبها الحقول.
قدرة النبضة الذروية
حاسبة هندسية لحساب قدرة النبضة الذروية وتقييم أثر المدخلات على النتيجة.
قدرة الذروة 70 W · طاقة النبضة 0.007 mJ · عرض النبضة 100 ns أساسيات الليزردورة التشغيل والحمل الحراري
حاسبة هندسية لحساب دورة التشغيل والحمل الحراري وتقييم أثر المدخلات على النتيجة.
دورة التشغيل 0.1 % · عرض النبضة 100 ns · معدل التكرار 10 kHz أساسيات الليزرالقدرة المتوسطة
حاسبة هندسية لحساب القدرة المتوسطة وتقييم أثر المدخلات على النتيجة.
الطاقة لكل نبضة 0.007 mJ · معدل التكرار 10 kHz أساسيات الليزرحجم البقعة عند المسافة z
حاسبة هندسية لحساب حجم البقعة عند المسافة z وتقييم أثر المدخلات على النتيجة.
قياس المدى وLiDARميزانية وصلة LiDAR
حاسبة هندسية لحساب ميزانية وصلة LiDAR وتقييم أثر المدخلات على النتيجة.
قراءات ذات صلة
ليزر ألياف متعددة الوضع موحد بقدرة 785 نانومتر: إضاءة متجانسة، بصريات محطة شاملة وحدود التحقق
دليل عملي لاستخدام ليزر ألياف موحدة بقدرة 785 نانومتر و90 مللي واط وقطر 200/340 ميكرومتر، يغطي انتظام الإضاءة، البصريات المساعدة لمحطة شاملة، حسابات القدرة والقياس.
البصريات905 نانومتر رامان DTS: تقرير تنفيذ الهندسة والتحقق
مسار هندسي كامل من مضخة نابضة 905 نانومتر وقنوات رامان تقريباً 870/943 نانومتر عبر APD مزدوج، الالتقاط المتزامن، تصحيح الفقد التفاضلي، انقلاب درجة الحرارة، المعايرة والتحقق من النموذج الأولي.
دليل الاختيار905 nm أم 1535 nm أم 1550 nm: اختيار الطول الموجي للقياس بالليزر والليدار
قرار الطول الموجي يحدّد الكاشف، وفئة أمان العين، وأقصى طاقة مسموح بها، والأداء في الأحوال الجوية. إليك مقارنة عملية بين النطاقات الثلاثة لعمل القياس بالليزر.