Guia de seleção
PLD905-70W-M vs OSRAM SPL TL90AT03: 70 W and 65 W 905 nm lasers
A datasheet comparison of PLD905-70W-M and OSRAM SPL TL90AT03 covering peak power, voltage, emitter geometry, thermal data, applications and replacement validation.
Atualizado 2026-11-16 · 3 min de leitura
PLD905-70W-M and OSRAM SPL TL90AT03 are both 905 nm TO56 metal-can lasers aimed at nanosecond pulse applications. The obvious difference is 70 W versus 65 W typical peak power, but voltage, emitter geometry and test conditions decide whether one can replace the other.
Product: PLD905-70W-M.
| Parameter | PLD905-70W-M | SPL TL90AT03 |
|---|---|---|
| Wavelength | 905 nm, 895-915 nm | 905 nm, 898-912 nm |
| Spectral width | 7 nm typical | 7 nm typical |
| Peak power | 70 W, 66-74 W table range | 65 W typical |
| Current | 20 A | 20 A |
| Standard repetition | 3 kHz | 1 kHz |
| Voltage | 15.6 V typical, 14.4-15.8 V | 9.5 V typical |
| Threshold current | 0.75 A typical | 0.3 A typical |
| Emitter | 90 x 18 um | 110 x 10 um |
| Divergence FWHM | 9 x 25 degrees | 10 x 25 degrees |
| Wavelength drift | 0.28 nm/K | Not listed |
| Maximum pulse width / duty | 100 ns / 0.1% | 100 ns / 0.1% |
The 5 W difference is about 7.7% of the 65 W value, but the standard repetition rates differ and the parts use different structures and operating points. It is not a same-condition measurement.
Driver and electrical checks
PLD905-70W-M needs significantly more compliance voltage. Before substitution, verify supply headroom, switch ratings, transformer design, loop inductance and reverse-spike protection. SPL TL90AT03 must also be operated within its own limits rather than the PLD limits.
Measure current, pulse width, edges, overshoot, reverse spikes, repetition, case temperature and sample-to-sample variation on the real board. Use the peak-power, duty-cycle and average-power calculators to check the electrical and thermal operating point.
Optical checks
The 90 x 18 um and 110 x 10 um emitters produce different near-field geometry and different fast/slow-axis collimation requirements. The FWHM divergence is only an input to the optical design, not the target spot size.
Measure the complete far field, collimator NA, alignment tolerance and target-plane spot. The spot-at-distance calculator provides a first footprint estimate.
Application boundaries
PLD905-70W-M can be evaluated for handheld ranging, golf, hunting, construction, UAV sensing and industrial distance measurement. SPL TL90AT03 also lists 3D sensing, gesture recognition, security and machine-control applications.
Neither datasheet makes the bare laser a certified finished product. The OSRAM document states that the component is not released for automotive use or developed as a safety- or medical-grade device. Missing qualification data for the other part must not be read as certification.
Use the LiDAR link-budget calculator when comparing complete ranging architectures.
Replacement sequence
- Confirm PLD905-70W-M suffix, pin option and package drawing.
- Compare driver voltage, current and pulse waveform.
- Measure optical power under identical pulse, repetition, temperature and current.
- Compare near field, far field and target-plane spot.
- Test low- and high-temperature power and wavelength drift.
- Recheck reverse-spike protection and complete-product eye safety.
Conclusion: 70 W versus 65 W is only the starting point. PLD905-70W-M is suitable for evaluation where the driver has enough voltage headroom and the PLD package is appropriate. OSRAM SPL TL90AT03 requires its own lower-voltage, three-emitter thermal design. A same-condition A/B test is mandatory before replacement.
Produtos
Produtos relacionados
Encapsulamento TO56
PLD905-70W-M
905 nm, pulsado, TO56
Calculadoras
Calcule com esta folha de dados
Cada calculadora abaixo abre com os valores da ficha desta peça já preenchidos, nas unidades pedidas pelos campos.
Potência de pico do pulso
Calculadora de engenharia para determinar potência de pico do pulso e avaliar o efeito dos dados de entrada no resultado.
Potência de pico 70 W · Pulse energy 0.007 mJ · Pulse width 100 ns Fundamentos do laserCiclo de trabalho e carga térmica
Calculadora de engenharia para determinar ciclo de trabalho e carga térmica e avaliar o efeito dos dados de entrada no resultado.
Ciclo de trabalho 0.1 % · Pulse width 100 ns · Repetition rate 10 kHz Fundamentos do laserPotência média
Calculadora de engenharia para determinar potência média e avaliar o efeito dos dados de entrada no resultado.
Energia por pulso 0.007 mJ · Repetition rate 10 kHz Fundamentos do laserTamanho do ponto à distância z
Calculadora de engenharia para determinar tamanho do ponto à distância z e avaliar o efeito dos dados de entrada no resultado.
Medição de distância e LiDAROrçamento de enlace LiDAR
Calculadora de engenharia para determinar orçamento de enlace lidar e avaliar o efeito dos dados de entrada no resultado.
Leituras relacionadas
Laser de fibra homogeneizada multimodo de 785 nm: iluminação uniforme, óptica de estação total e limites de validação
Guia prático de um laser de fibra homogeneizada de 785 nm, 90 mW, 200/340 um, abordando uniformidade de iluminação, óptica auxiliar de estação total, orçamento de potência e medição.
Óptica905 nm Raman DTS: relatório de implementação e validação de engenharia
Uma rota completa de engenharia a partir de uma bomba pulsada de 905 nm e aproximadamente canais Raman de 870/943 nm através de APDs duplos, aquisição síncrona, correção de perda diferencial, inversão de temperatura, calibração e validação de protótipo.
Guia de seleção905 nm, 1535 nm e 1550 nm: como escolher o comprimento de onda para medição de distância e LiDAR
O comprimento de onda define o detector, a classe de segurança ocular, a energia máxima utilizável e o desempenho sob condições climáticas. Veja como as três faixas se comparam.