Optics

1550 nm Raman DTS: distributed fibre temperature sensing implementation

A 1550 nm pulsed-source Raman DTS plan covering dual anti-Stokes/Stokes channels, OTDR location, BOM, APD receivers, FPGA accumulation, temperature inversion, calibration and 10 km acceptance.

Updated 2026-11-24 · 11 min read


A pulsed laser launches light into a multimode or single-mode fibre. Every fibre position generates spontaneous Raman backscatter. The anti-Stokes band is temperature-sensitive, the Stokes band serves as a reference, and the ratio provides local temperature after calibration. Arrival time locates the scattering point:

z = c * t / (2n)

For a 1550 nm pump in silica, the Raman shift is about 13.2 THz, or 440 cm-1. The anti-Stokes channel is near 1450 nm, Stokes near 1663 nm, and Rayleigh remains near 1550 nm. Raman scattering is roughly 30 dB below Rayleigh and 60-70 dB below the launch pulse, so the source must combine short pulses, high peak power and high extinction ratio.

Typical applications include cable tunnels, high-voltage cables, GIL, substation trenches, pipelines, tanks, LNG facilities, downhole profiles, tunnel and metro fire detection, dam seepage, battery rooms and data-centre hot-spot monitoring.

Standard-product targetValueNote
Range<=10 km standard, 30 km long rangePer channel
Spatial resolution1 m10 ns pulse
Sampling interval0.4 m at 250 MS/sConfigurable 0.25-1 m
Temperature range-40 to +120 °C ordinary cable; 300 °C high-temperature cableCable coating dependent
Temperature accuracy+/-1 °C at 10 kmEnd of fibre
Temperature resolution0.1 °C30 s averaging
Measurement time<=10 s per channel for alarm productConfigurable averaging
Channels1/2/4/8/16 with optical switchExpandable
CommunicationRS485, Ethernet, Modbus, IEC 61850 and dry contactsSCADA integration

1 Source selection

Use an integrated DTS pulsed fibre laser, or a MOPA architecture with DFB seed, external/direct modulation and two EDFA stages. The source specification dominates SNR, resolution and nonlinear limits.

ParameterRecommendationReason
Centre wavelength1550 +/-5 nmLow fibre loss around 0.2 dB/km and mature components; 1064 nm can be considered for short multimode systems
Pulse width10 ns, adjustable 5-20 nsAbout 1 m resolution
Peak power10-20 W multimode; 1-5 W single modeHigher power risks stimulated Raman scattering and distortion
Repetition rate1-20 kHzf <= c/(2nL); about 10 kHz at 10 km and 3.3 kHz at 30 km
Extinction ratio>40 dB, preferably >50 dBLeakage between pulses raises the noise floor
Spectral width<=1 nm, ASE suppression >40 dBASE near 1450/1663 nm enters the receiver directly
Peak-power stability<1% RMS over 1 hRatio cancellation is incomplete
Rise/fall<2 nsPreserves resolution
TriggerIsolated TTL with <1 ns jitterMust synchronise ADC acquisition
Fibre50/125 or 62.5/125 multimode, or G.652 single modeMultimode gives stronger Raman return over <=10 km
Temperature-10 to +55 °C with TECSource wavelength and power stability

Multimode route below 10-15 km: stronger Raman signal, 10-20 W allowed peak, +/-0.5-1 °C at 10 km and lower cost. Single-mode route for >10 km: G.652, 1-5 W peak, lower Raman signal and more averaging, typically +/-1-2 °C at 30 km.

ItemMultimode, preferred <=10 kmSingle mode, long range >10 km
Sensing fibre50/125 or 62.5/125 multimodeG.652 single mode
Raman signalStronger due to higher NA and core acceptanceWeaker; more averaging required
Allowed peak power10-20 W1-5 W
Range<=10-15 km, limited by mode dispersion and lossMore than 30 km
Typical accuracy+/-0.5-1 °C at 10 km+/-1-2 °C at 30 km
CostLowerHigher APD and averaging requirements

2 Optical and electronic architecture

Optical chain:

1550 nm pulse laser -> isolator -> ASE bandpass filter -> Raman WDM common port

The WDM sends 1450 nm anti-Stokes and 1663 nm Stokes to separate APD/TIA receivers. A 1xN switch, temperature-controlled reference fibre loop and sensing cable complete the path.

Raman WDM requirements are critical: >40 dB rejection of 1550 nm Rayleigh light and >35 dB isolation between anti-Stokes and Stokes. A 100-200 m reference fibre inside the instrument is held at known temperature with a PT100 so source and APD drift can be tracked. APC connectors or fusion splices reduce Fresnel reflection, dead zone and saturation.

Electronics:

  • InGaAs APDs with at least 100 MHz bandwidth and 40-70 V bias, temperature-compensated to hold gain.
  • Adjustable TIA and main amplifier around 100 MHz.
  • Two 14-bit, at least 250 MS/s ADCs sampling synchronously.
  • FPGA accumulation with at least 32-bit width and 100,000 points per frame, supporting 10^4 to 10^6 averages.
  • ARM or industrial computer for temperature inversion, zone alarms, history and communications.

3 BOM

The reference is a four-channel, 10 km, 1 m multimode DTS host. Prices are domestic small-volume references.

Optical itemRequirementQtyReference cost
Pulsed fibre laser>=20 W peak, 5-20 ns, 1-20 kHz, extinction >40 dB, ASE suppression >40 dB, multimode pigtail1RMB 12,000
IsolatorMatching 1550 nm, >=35 dB1RMB 150
ASE filter1550 +/-3 nm, out-of-band rejection >45 dB1RMB 300
Raman WDM1550/1450/1663 nm, Rayleigh isolation >40 dB, channel isolation >35 dB, IL <1.2 dB1RMB 2,500
Optical switch1x4 multimode mechanical/MEMS, repeatability <0.05 dB1RMB 1,500
Reference fibre200 m matched multimode in a temperature-controlled enclosure1RMB 200
InGaAs APD900-1700 nm, >=100 MHz, M>=10, pigtail and temperature sensor2RMB 3,000 total
Sensing cableFour-core multimode, stainless tube and flame-retardant jacket10 kmRMB 30,000
Patch/splice hardwareFC/APC and splice protection1 lotRMB 500

Electronic material:

ItemRequirementQtyUse
FPGA+ARM SoC>=85K logic, >=200 DSP, >=1 GB DDR31Capture, averaging and inversion
ADCDual 14-bit, >=250 MS/s, JESD204B/LVDS1Simultaneous anti-Stokes/Stokes
ClockJitter <200 fs1ADC/FPGA timing
TIA/main ampGBW >=1 GHz, input noise <2 nV/sqrt-Hz4APD amplification
APD biasProgrammable 0-80 V, ripple <1 mV2Detector bias
Temperature controlTEC and 24-bit PT100 acquisition1 setAPD and reference loop
Laser triggerIsolated TTL, jitter <1 ns1Pulse sync
PowerWide input DC-DC and low-noise LDO1 setSupply
CommunicationTwo Ethernet, RS485 and 16 dry contacts1 setSCADA and alarms
Storage32 GB eMMC and SD1 setProfiles and events
PCBEight layers with analog/digital isolation1Main board

Structure and software include a 19-inch 2U shielded chassis with fan control, a +/-0.1 °C enclosure for the reference loop and APDs, fibre hardware, embedded acquisition/accumulation/alarm firmware and host software for temperature curves, zones, heat maps, history and calibration.

ItemDescriptionQty
Chassis19-inch 2U, sheet-metal shielding and temperature-controlled fan1
Temperature chamberHouses reference fibre and APDs, +/-0.1 °C1
Cable hardwareJoint boxes, clamps and termination boxes1 lot
Embedded firmwareCapture, accumulation, inversion, alarm and Modbus/IEC 61850-
Host softwareTemperature curves, zones, heat map, replay and calibration wizard-

Estimated host optical material about RMB 20,000 excluding sensing cable, electronics about RMB 8,000, structure about RMB 2,000, host material about RMB 30,000, and 10 km sensing cable about RMB 30,000.

Cost itemReference amount
Optics excluding sensing cableAbout RMB 20,000
ElectronicsAbout RMB 8,000
StructureAbout RMB 2,000
Host material subtotalAbout RMB 30,000
10 km sensing cable at RMB 3/mAbout RMB 30,000, project dependent

4 APD and acquisition design

Set APD bias near 0.9 times breakdown, but compensate the 0.1-0.2 V/°C breakdown drift by temperature lookup or a controlled thermal enclosure. Use matched APDs from the same batch for the two channels. Add 5-10 m delay fibre and front-end limiting to prevent strong near-end reflection from saturating the detector.

The FPGA trigger and ADC clock should share a time base. Record enough points for the full fibre window: 10 km corresponds to about 100 us and 25,000 points at 250 MS/s. Accumulate in 32-bit memory. SNR improves approximately with sqrt(N); 10 km multimode commonly needs 20,000-50,000 averages and 3-10 s measurement time.

Shield the high-speed analog section and keep the APD high-voltage supply away from the TIA. Acquire a laser-off dark frame before each measurement to subtract offset and electronic noise.

5 Temperature inversion

The anti-Stokes/Stokes ratio is:

R(z) = I_AS(z) / I_S(z)

R(z) = K * (lambda_S/lambda_AS)^4 * exp(-h*delta-v/(kB*T(z))) * exp(-integral(alpha_AS-alpha_S)dz)

For a 13.2 THz shift, h*delta-v/kB is about 633 K. Use a reference temperature T0 and reference ratio R(z0):

T(z) = gamma / [gamma/T0 - ln(R(z)/R(z0)) + delta-alpha*(z-z0)]

where delta-alpha is the calibrated differential-loss coefficient.

Processing:

  1. Accumulate N pulses.
  2. Subtract the dark frame.
  3. Interpolate the two channels to remove dispersion delay, typically 0.5-1 m at 10 km.
  4. Denoise along distance with db4 wavelet 3-5 levels or Savitzky-Golay, never wider than the spatial-resolution cell.
  5. Compute the ratio and correct differential attenuation.
  6. Invert temperature using the live reference-loop T0 and R(z0).
  7. Output maximum/average temperature and rate of rise by zone.

Differential-loss calibration may use a uniform-temperature single-ended fit, a two-ended geometric-mean method, near/far reference zones, or an added Rayleigh 1550 nm channel to identify bends and breaks. The two-ended method is preferred for long-range or high accuracy, at the cost of halving channel count.

Hot spots shorter than the resolution cell are averaged and underestimated. Wiener deconvolution of the pulse response can restore peak temperature when regularised with experimental data. For alarms, compare a rolling baseline such as a 24-hour median and require several confirmations before reporting.

Drift compensation uses the reference-loop ratio every frame, APD thermal control and bias lookup, and a +/-0.1 °C PT100 as the temperature anchor.

6 Calibration and commissioning

Required equipment: two baths from -20 to 150 °C with +/-0.05 °C uniformity; standard PRT and bridge; OTDR; >=1 GHz optical waveform and power measurement; variable attenuator and 1/5/10 km delay reels.

EquipmentRequirementUse
Two baths/oil baths-20 to 150 °C, +/-0.05 °CMulti-point temperature calibration
Standard PRTSecondary standard plus bridgeTraceable temperature
OTDR850/1300 nm multimode; 1550 nm single modeFibre loss and break inspection
Power meter/oscilloscope>=1 GHz bandwidthPulse waveform and power
Variable attenuator and delay fibre0-30 dB and 1/5/10 kmDynamic-range testing

Host setup:

  1. Measure pulse width near 10 ns, rise <2 ns, peak power, extinction and trigger jitter.
  2. Inject 1550/1450/1663 nm light and verify WDM isolation.
  3. Measure APD breakdown in darkness, then generate gain and dark-current versus bias/temperature tables near 0.9 times breakdown.
  4. Connect 10 km fibre and check no near-end saturation and far-end SNR >10 dB after 20,000 averages.
  5. Heat a 2 m section and compare anti-Stokes/Stokes hot-spot positions to determine dispersion delay.
  6. With the full fibre at uniform room temperature, calibrate R(z0), time zero and delta-alpha.
  7. Put a >=10 m section in the bath at 0/25/50/75/100 °C, fit gamma and bias, and require residual <0.3 °C.
  8. Heat 1 m from room temperature to 50 °C and check the 10-90% spatial response <=1 m.
  9. Run 72 hours; standard deviation at the 10 km end should be <=0.5 °C.

Field commissioning starts with OTDR attenuation, a cable-metre-to-zone map, and a location marker every 100 m if possible. Compare two or three portable reference thermometers, configure fixed-temperature, differential-temperature and rate-of-rise alarms, and verify every SCADA point and dry contact.

7 Acceptance

TestMethodAcceptance
Range10 km cableValid temperature over full length
Spatial resolution1 m heated section, 10-90%<=1 m
Temperature accuracyThree bath points at fibre end<= +/-1 °C
Temperature resolution30 s average at stable temperature<=0.1 °C near end, <=0.3 °C far end
Location accuracyKnown cable marker and heater<= +/-1 m
Response timeStep heating to alarm<=30 s, referencing applicable fire-detector standard
Fibre breakCut cableAlarm within one acquisition cycle and locate within +/-2 m
Environment/EMC-10 to 55 °C, GB/T 17626 level 4Normal function and accuracy
Long run168 hNo drift failure or crash

8 Risks

RiskEffectControl
Excessive peak power causes SRSFar-end temperature distortionSet peak power by fibre type and factory-test power/temperature linearity
Bend/age changes delta-alphaDistance-dependent driftTwo-ended or dual reference; periodic zero recalibration
Hydrogen loss in chemical or downhole useIncreased attenuation near 1450 nmHydrogen-resistant cable and two-ended measurement
Near-end reflection saturates APDDead zoneDelay fibre, APC connectors and limiting
APD temperature driftRatio errorThermal enclosure, bias loop and live reference normalisation
False alarmsOperating burdenRolling baseline, multi-frame confirmation and zone thresholds

9 Project plan

StageWorkWeeksDeliverable
M1Source, WDM and APD purchase and evaluation1-4Device report
M2Receive/acquisition boards and optical integration5-10Prototype hardware
M3FPGA accumulation, inversion, dispersion/loss correction and host UI7-14Firmware V1.0
M4Calibration, acceptance and environmental testing15-18Test report
M5Site installation and 30-day trial19-24Pilot report

Recommended next step: buy one 1550 nm pulsed fibre-laser sample, one Raman WDM and two APDs. Build the 10 km multimode bench, complete steps 1-7 of the host setup, and prove +/-1 °C at the far end before releasing the production PCB.

Source document

Download the complete Chinese implementation plan. It contains the full BOM, acceptance tables, algorithm notes, risk register and implementation schedule.


Related reading

Have a specification, not a part number?

Send us the requirement - range, target, size, budget - and an engineer will come back with parts and the trade-offs between them.

Ask an engineer