1550 nm Raman DTS: distributed fibre temperature sensing implementation
A 1550 nm pulsed-source Raman DTS plan covering dual anti-Stokes/Stokes channels, OTDR location, BOM, APD receivers, FPGA accumulation, temperature inversion, calibration and 10 km acceptance.
Updated 2026-11-24 · 11 min read
A pulsed laser launches light into a multimode or single-mode fibre. Every fibre position generates spontaneous Raman backscatter. The anti-Stokes band is temperature-sensitive, the Stokes band serves as a reference, and the ratio provides local temperature after calibration. Arrival time locates the scattering point:
z = c * t / (2n)
For a 1550 nm pump in silica, the Raman shift is about 13.2 THz, or 440 cm-1. The anti-Stokes channel is near 1450 nm, Stokes near 1663 nm, and Rayleigh remains near 1550 nm. Raman scattering is roughly 30 dB below Rayleigh and 60-70 dB below the launch pulse, so the source must combine short pulses, high peak power and high extinction ratio.
Typical applications include cable tunnels, high-voltage cables, GIL, substation trenches, pipelines, tanks, LNG facilities, downhole profiles, tunnel and metro fire detection, dam seepage, battery rooms and data-centre hot-spot monitoring.
| Standard-product target | Value | Note |
|---|---|---|
| Range | <=10 km standard, 30 km long range | Per channel |
| Spatial resolution | 1 m | 10 ns pulse |
| Sampling interval | 0.4 m at 250 MS/s | Configurable 0.25-1 m |
| Temperature range | -40 to +120 °C ordinary cable; 300 °C high-temperature cable | Cable coating dependent |
| Temperature accuracy | +/-1 °C at 10 km | End of fibre |
| Temperature resolution | 0.1 °C | 30 s averaging |
| Measurement time | <=10 s per channel for alarm product | Configurable averaging |
| Channels | 1/2/4/8/16 with optical switch | Expandable |
| Communication | RS485, Ethernet, Modbus, IEC 61850 and dry contacts | SCADA integration |
1 Source selection
Use an integrated DTS pulsed fibre laser, or a MOPA architecture with DFB seed, external/direct modulation and two EDFA stages. The source specification dominates SNR, resolution and nonlinear limits.
| Parameter | Recommendation | Reason |
|---|---|---|
| Centre wavelength | 1550 +/-5 nm | Low fibre loss around 0.2 dB/km and mature components; 1064 nm can be considered for short multimode systems |
| Pulse width | 10 ns, adjustable 5-20 ns | About 1 m resolution |
| Peak power | 10-20 W multimode; 1-5 W single mode | Higher power risks stimulated Raman scattering and distortion |
| Repetition rate | 1-20 kHz | f <= c/(2nL); about 10 kHz at 10 km and 3.3 kHz at 30 km |
| Extinction ratio | >40 dB, preferably >50 dB | Leakage between pulses raises the noise floor |
| Spectral width | <=1 nm, ASE suppression >40 dB | ASE near 1450/1663 nm enters the receiver directly |
| Peak-power stability | <1% RMS over 1 h | Ratio cancellation is incomplete |
| Rise/fall | <2 ns | Preserves resolution |
| Trigger | Isolated TTL with <1 ns jitter | Must synchronise ADC acquisition |
| Fibre | 50/125 or 62.5/125 multimode, or G.652 single mode | Multimode gives stronger Raman return over <=10 km |
| Temperature | -10 to +55 °C with TEC | Source wavelength and power stability |
Multimode route below 10-15 km: stronger Raman signal, 10-20 W allowed peak, +/-0.5-1 °C at 10 km and lower cost. Single-mode route for >10 km: G.652, 1-5 W peak, lower Raman signal and more averaging, typically +/-1-2 °C at 30 km.
| Item | Multimode, preferred <=10 km | Single mode, long range >10 km |
|---|---|---|
| Sensing fibre | 50/125 or 62.5/125 multimode | G.652 single mode |
| Raman signal | Stronger due to higher NA and core acceptance | Weaker; more averaging required |
| Allowed peak power | 10-20 W | 1-5 W |
| Range | <=10-15 km, limited by mode dispersion and loss | More than 30 km |
| Typical accuracy | +/-0.5-1 °C at 10 km | +/-1-2 °C at 30 km |
| Cost | Lower | Higher APD and averaging requirements |
2 Optical and electronic architecture
Optical chain:
1550 nm pulse laser -> isolator -> ASE bandpass filter -> Raman WDM common port
The WDM sends 1450 nm anti-Stokes and 1663 nm Stokes to separate APD/TIA receivers. A 1xN switch, temperature-controlled reference fibre loop and sensing cable complete the path.
Raman WDM requirements are critical: >40 dB rejection of 1550 nm Rayleigh light and >35 dB isolation between anti-Stokes and Stokes. A 100-200 m reference fibre inside the instrument is held at known temperature with a PT100 so source and APD drift can be tracked. APC connectors or fusion splices reduce Fresnel reflection, dead zone and saturation.
Electronics:
- InGaAs APDs with at least 100 MHz bandwidth and 40-70 V bias, temperature-compensated to hold gain.
- Adjustable TIA and main amplifier around 100 MHz.
- Two 14-bit, at least 250 MS/s ADCs sampling synchronously.
- FPGA accumulation with at least 32-bit width and 100,000 points per frame, supporting 10^4 to 10^6 averages.
- ARM or industrial computer for temperature inversion, zone alarms, history and communications.
3 BOM
The reference is a four-channel, 10 km, 1 m multimode DTS host. Prices are domestic small-volume references.
| Optical item | Requirement | Qty | Reference cost |
|---|---|---|---|
| Pulsed fibre laser | >=20 W peak, 5-20 ns, 1-20 kHz, extinction >40 dB, ASE suppression >40 dB, multimode pigtail | 1 | RMB 12,000 |
| Isolator | Matching 1550 nm, >=35 dB | 1 | RMB 150 |
| ASE filter | 1550 +/-3 nm, out-of-band rejection >45 dB | 1 | RMB 300 |
| Raman WDM | 1550/1450/1663 nm, Rayleigh isolation >40 dB, channel isolation >35 dB, IL <1.2 dB | 1 | RMB 2,500 |
| Optical switch | 1x4 multimode mechanical/MEMS, repeatability <0.05 dB | 1 | RMB 1,500 |
| Reference fibre | 200 m matched multimode in a temperature-controlled enclosure | 1 | RMB 200 |
| InGaAs APD | 900-1700 nm, >=100 MHz, M>=10, pigtail and temperature sensor | 2 | RMB 3,000 total |
| Sensing cable | Four-core multimode, stainless tube and flame-retardant jacket | 10 km | RMB 30,000 |
| Patch/splice hardware | FC/APC and splice protection | 1 lot | RMB 500 |
Electronic material:
| Item | Requirement | Qty | Use |
|---|---|---|---|
| FPGA+ARM SoC | >=85K logic, >=200 DSP, >=1 GB DDR3 | 1 | Capture, averaging and inversion |
| ADC | Dual 14-bit, >=250 MS/s, JESD204B/LVDS | 1 | Simultaneous anti-Stokes/Stokes |
| Clock | Jitter <200 fs | 1 | ADC/FPGA timing |
| TIA/main amp | GBW >=1 GHz, input noise <2 nV/sqrt-Hz | 4 | APD amplification |
| APD bias | Programmable 0-80 V, ripple <1 mV | 2 | Detector bias |
| Temperature control | TEC and 24-bit PT100 acquisition | 1 set | APD and reference loop |
| Laser trigger | Isolated TTL, jitter <1 ns | 1 | Pulse sync |
| Power | Wide input DC-DC and low-noise LDO | 1 set | Supply |
| Communication | Two Ethernet, RS485 and 16 dry contacts | 1 set | SCADA and alarms |
| Storage | 32 GB eMMC and SD | 1 set | Profiles and events |
| PCB | Eight layers with analog/digital isolation | 1 | Main board |
Structure and software include a 19-inch 2U shielded chassis with fan control, a +/-0.1 °C enclosure for the reference loop and APDs, fibre hardware, embedded acquisition/accumulation/alarm firmware and host software for temperature curves, zones, heat maps, history and calibration.
| Item | Description | Qty |
|---|---|---|
| Chassis | 19-inch 2U, sheet-metal shielding and temperature-controlled fan | 1 |
| Temperature chamber | Houses reference fibre and APDs, +/-0.1 °C | 1 |
| Cable hardware | Joint boxes, clamps and termination boxes | 1 lot |
| Embedded firmware | Capture, accumulation, inversion, alarm and Modbus/IEC 61850 | - |
| Host software | Temperature curves, zones, heat map, replay and calibration wizard | - |
Estimated host optical material about RMB 20,000 excluding sensing cable, electronics about RMB 8,000, structure about RMB 2,000, host material about RMB 30,000, and 10 km sensing cable about RMB 30,000.
| Cost item | Reference amount |
|---|---|
| Optics excluding sensing cable | About RMB 20,000 |
| Electronics | About RMB 8,000 |
| Structure | About RMB 2,000 |
| Host material subtotal | About RMB 30,000 |
| 10 km sensing cable at RMB 3/m | About RMB 30,000, project dependent |
4 APD and acquisition design
Set APD bias near 0.9 times breakdown, but compensate the 0.1-0.2 V/°C breakdown drift by temperature lookup or a controlled thermal enclosure. Use matched APDs from the same batch for the two channels. Add 5-10 m delay fibre and front-end limiting to prevent strong near-end reflection from saturating the detector.
The FPGA trigger and ADC clock should share a time base. Record enough points for the full fibre window: 10 km corresponds to about 100 us and 25,000 points at 250 MS/s. Accumulate in 32-bit memory. SNR improves approximately with sqrt(N); 10 km multimode commonly needs 20,000-50,000 averages and 3-10 s measurement time.
Shield the high-speed analog section and keep the APD high-voltage supply away from the TIA. Acquire a laser-off dark frame before each measurement to subtract offset and electronic noise.
5 Temperature inversion
The anti-Stokes/Stokes ratio is:
R(z) = I_AS(z) / I_S(z)
R(z) = K * (lambda_S/lambda_AS)^4 * exp(-h*delta-v/(kB*T(z))) * exp(-integral(alpha_AS-alpha_S)dz)
For a 13.2 THz shift, h*delta-v/kB is about 633 K. Use a reference temperature T0 and reference ratio R(z0):
T(z) = gamma / [gamma/T0 - ln(R(z)/R(z0)) + delta-alpha*(z-z0)]
where delta-alpha is the calibrated differential-loss coefficient.
Processing:
- Accumulate N pulses.
- Subtract the dark frame.
- Interpolate the two channels to remove dispersion delay, typically 0.5-1 m at 10 km.
- Denoise along distance with db4 wavelet 3-5 levels or Savitzky-Golay, never wider than the spatial-resolution cell.
- Compute the ratio and correct differential attenuation.
- Invert temperature using the live reference-loop T0 and R(z0).
- Output maximum/average temperature and rate of rise by zone.
Differential-loss calibration may use a uniform-temperature single-ended fit, a two-ended geometric-mean method, near/far reference zones, or an added Rayleigh 1550 nm channel to identify bends and breaks. The two-ended method is preferred for long-range or high accuracy, at the cost of halving channel count.
Hot spots shorter than the resolution cell are averaged and underestimated. Wiener deconvolution of the pulse response can restore peak temperature when regularised with experimental data. For alarms, compare a rolling baseline such as a 24-hour median and require several confirmations before reporting.
Drift compensation uses the reference-loop ratio every frame, APD thermal control and bias lookup, and a +/-0.1 °C PT100 as the temperature anchor.
6 Calibration and commissioning
Required equipment: two baths from -20 to 150 °C with +/-0.05 °C uniformity; standard PRT and bridge; OTDR; >=1 GHz optical waveform and power measurement; variable attenuator and 1/5/10 km delay reels.
| Equipment | Requirement | Use |
|---|---|---|
| Two baths/oil baths | -20 to 150 °C, +/-0.05 °C | Multi-point temperature calibration |
| Standard PRT | Secondary standard plus bridge | Traceable temperature |
| OTDR | 850/1300 nm multimode; 1550 nm single mode | Fibre loss and break inspection |
| Power meter/oscilloscope | >=1 GHz bandwidth | Pulse waveform and power |
| Variable attenuator and delay fibre | 0-30 dB and 1/5/10 km | Dynamic-range testing |
Host setup:
- Measure pulse width near 10 ns, rise <2 ns, peak power, extinction and trigger jitter.
- Inject 1550/1450/1663 nm light and verify WDM isolation.
- Measure APD breakdown in darkness, then generate gain and dark-current versus bias/temperature tables near 0.9 times breakdown.
- Connect 10 km fibre and check no near-end saturation and far-end SNR >10 dB after 20,000 averages.
- Heat a 2 m section and compare anti-Stokes/Stokes hot-spot positions to determine dispersion delay.
- With the full fibre at uniform room temperature, calibrate R(z0), time zero and delta-alpha.
- Put a >=10 m section in the bath at 0/25/50/75/100 °C, fit gamma and bias, and require residual <0.3 °C.
- Heat 1 m from room temperature to 50 °C and check the 10-90% spatial response <=1 m.
- Run 72 hours; standard deviation at the 10 km end should be <=0.5 °C.
Field commissioning starts with OTDR attenuation, a cable-metre-to-zone map, and a location marker every 100 m if possible. Compare two or three portable reference thermometers, configure fixed-temperature, differential-temperature and rate-of-rise alarms, and verify every SCADA point and dry contact.
7 Acceptance
| Test | Method | Acceptance |
|---|---|---|
| Range | 10 km cable | Valid temperature over full length |
| Spatial resolution | 1 m heated section, 10-90% | <=1 m |
| Temperature accuracy | Three bath points at fibre end | <= +/-1 °C |
| Temperature resolution | 30 s average at stable temperature | <=0.1 °C near end, <=0.3 °C far end |
| Location accuracy | Known cable marker and heater | <= +/-1 m |
| Response time | Step heating to alarm | <=30 s, referencing applicable fire-detector standard |
| Fibre break | Cut cable | Alarm within one acquisition cycle and locate within +/-2 m |
| Environment/EMC | -10 to 55 °C, GB/T 17626 level 4 | Normal function and accuracy |
| Long run | 168 h | No drift failure or crash |
8 Risks
| Risk | Effect | Control |
|---|---|---|
| Excessive peak power causes SRS | Far-end temperature distortion | Set peak power by fibre type and factory-test power/temperature linearity |
| Bend/age changes delta-alpha | Distance-dependent drift | Two-ended or dual reference; periodic zero recalibration |
| Hydrogen loss in chemical or downhole use | Increased attenuation near 1450 nm | Hydrogen-resistant cable and two-ended measurement |
| Near-end reflection saturates APD | Dead zone | Delay fibre, APC connectors and limiting |
| APD temperature drift | Ratio error | Thermal enclosure, bias loop and live reference normalisation |
| False alarms | Operating burden | Rolling baseline, multi-frame confirmation and zone thresholds |
9 Project plan
| Stage | Work | Weeks | Deliverable |
|---|---|---|---|
| M1 | Source, WDM and APD purchase and evaluation | 1-4 | Device report |
| M2 | Receive/acquisition boards and optical integration | 5-10 | Prototype hardware |
| M3 | FPGA accumulation, inversion, dispersion/loss correction and host UI | 7-14 | Firmware V1.0 |
| M4 | Calibration, acceptance and environmental testing | 15-18 | Test report |
| M5 | Site installation and 30-day trial | 19-24 | Pilot report |
Recommended next step: buy one 1550 nm pulsed fibre-laser sample, one Raman WDM and two APDs. Build the 10 km multimode bench, complete steps 1-7 of the host setup, and prove +/-1 °C at the far end before releasing the production PCB.
Source document
Download the complete Chinese implementation plan. It contains the full BOM, acceptance tables, algorithm notes, risk register and implementation schedule.
Related reading
785 nm multimode homogenized-fiber laser: uniform illumination, total-station optics and validation limits
A practical guide to a 785 nm, 90 mW, 200/340 um homogenized-fiber laser, covering illumination uniformity, total-station auxiliary optics, power budgeting and measurement.
Optics905 nm Raman DTS: engineering implementation and validation report
A complete engineering route from a 905 nm pulsed pump and approximately 870/943 nm Raman channels through dual APDs, synchronous acquisition, differential-loss correction, temperature inversion, calibration and prototype validation.
Selection guide905 nm vs 1535 nm vs 1550 nm: choosing a wavelength for ranging and LiDAR
The wavelength decision sets your detector, your eye-safety class, your maximum usable energy and your weather performance. Here is how the three bands actually compare for ranging work.