Selection guide
LTPGAU1S09 vs PLD905-75W-M: choosing between two 75 W class 905 nm pulsed lasers
A datasheet-based comparison of Excelitas LTPGAU1S09 and PLD905-75W-M covering their three-layer structure, 75 W typical power, 1 kHz and 3 kHz conditions, 30 A drive, spectrum, thermal drift, TO56 pinout and application boundaries.
Updated 2026-11-27 · 11 min read
PLD905-75W-M and Excelitas LTPGAU1S09 are both positioned as 905 nm, 75 W class pulsed sources for ranging, use a three-layer emitter/cavity approach and come in 5.6 mm class metal TO packages. The main differences are test frequency, emitter length, electrical operating point, temperature specifications and package details.
Both datasheets quote a 75 W typical value, but the Excelitas table uses 100 ns and 1 kHz while the PLD standard condition is 100 ns, 3 kHz and 30 A. The two watt figures must not be treated as a complete same-condition result.
Main conclusion: Evaluate LTPGAU1S09 first when the system values the wider cold operating and storage range, lower wavelength temperature coefficient, 5 nm spectral width and the Excelitas C30737 epi-APD ecosystem. Evaluate PLD905-75W-M first when the validation plan uses 100 ns, 3 kHz and 30 A, multiple TO56 pin/pitch variants are useful, and drone or handheld ranging applications matter. Final selection still requires measurement with the same driver, optics and receive chain.
Executive summary: similar power class, different system priorities
| Comparison | Excelitas LTPGAU1S09 | PLD905-75W-M | Engineering consequence |
|---|---|---|---|
| Centre wavelength | 905 nm typical; 895-915 nm | 905 nm typical; 895-915 nm | Both match common 905 nm silicon-detector ranging systems |
| Typical peak power | 75 W; 70 W minimum | 75 W; 65 W minimum and 80 W maximum | Typical values match, but test frequency and grading methods differ |
| Typical test condition | 100 ns, 1 kHz | 100 ns, 3 kHz, 30 A, 25 °C | Thermal load and output cannot be ranked from power alone |
| Emitter | 225 x 10 um | 200 x 10 um | The PLD long axis is about 11.1% shorter; system spot reduction is not implied |
| Spectral width FWHM | 5 nm typical | 7 nm typical | Excelitas is nominally narrower, but filter and drift validation remain necessary |
| Operating temperature | -55 to +85 °C | -40 to +85 °C | Excelitas specifies the lower cold limit |
These similarities and differences support initial screening, not direct conclusions about measured range, lifetime, production yield or complete-system cost.
Device overview


Detailed specification comparison
| Parameter | Excelitas LTPGAU1S09 | PLD905-75W-M | Objective interpretation |
|---|---|---|---|
| Device route | LU-series Multi-epi; three emitting stripes/cavities | Nanoscale stacked laser; three epitaxial stacked emitters | Both use a three-layer/cavity route; deeper epitaxial detail requires supplier clarification |
| Centre wavelength | 905 nm typical; 895-915 nm spectral envelope | 905 nm typical; 895-915 nm | Nominal ranges are close; match the filter bandwidth and operating temperature |
| Spectral width FWHM | 5 nm typical | 7 nm typical | Excelitas is nominally narrower; benefit depends on filter, drift and detector response |
| Peak optical power | 70 W minimum, 75 W typical; 100 ns, 1 kHz | 65 W minimum, 75 W typical, 80 W maximum; 100 ns, 3 kHz, 30 A | Typical values match, but test and grading methods are not identical |
| Emitter | 225 x 10 um | 200 x 10 um | The PLD long axis is about 11.1% shorter; target-plane spot cannot be inferred |
| Divergence parallel to PN | 10° typical | 9° typical, 10° maximum | Typical values are close; PLD gives an explicit maximum |
| Divergence perpendicular to PN | 25° typical | 25° typical, 28° maximum | Typical values are close; batch spread still requires measurement |
| Typical threshold current | 1.75 A | 0.75 A | A lower threshold does not establish higher system efficiency or reliability |
| Operating current | 30 A listed peak-drive limit | 25 A minimum, 30 A typical, 32 A maximum | PLD gives a more complete operating range |
| Typical forward voltage | 12.8 V at 30 A, estimated from series resistance and bandgap | 16.8 V at 30 A | PLD requires a larger voltage budget and rechecking switching loss |
| Series resistance / bandgap voltage | 0.21 ohm / 6.5 V typical | Not listed in the supplied table | PLD internal equivalent resistance cannot be inferred |
| Wavelength temperature coefficient | 0.25 nm/°C typical | 0.28 nm/K typical | Excelitas is nominally lower; system temperature sweeps remain necessary |
| Operating temperature | -55 to +85 °C | -40 to +85 °C | Excelitas extends lower; this does not mean constant performance over the range |
| Storage temperature | -55 to +105 °C | -40 to +100 °C | Excelitas specifies a wider range; storage limits are not operating limits |
| Pulse width | 100 ns maximum rating | 100 ns maximum rating; 1-100 ns short-pulse applicability | Both share the 100 ns ceiling; shorter pulses require new drive and power validation |
| Maximum duty cycle | 0.1% | 0.1% | Pulse width, rate, case temperature and long-term heat must all remain inside limits |
| Reverse-voltage rating | 6 V | 20 V | Definitions may differ; a larger number does not justify larger reverse transients |
| Package | 5.6 mm hermetic metal TO, three pins | TO56 metal package, several pin/pitch variants | Similar outlines are not direct replacements |
| Package inductance | 5 nH | Not listed | Missing PLD data does not mean lower inductance; request or measure it |
The Excelitas values come from the LTPGAU1S09 column of the LU-series Preliminary Data Sheet. Common series values are stated at 23 °C, and the electro-optical table uses 100 ns and 1 kHz. PLD data follows PLD905-75W-M V3.0 at 100 ns, 3 kHz, 30 A and 25 °C.
Optical behaviour: spectrum and emitter geometry differ


| Optical item | Excelitas LTPGAU1S09 | PLD905-75W-M | Engineering interpretation |
|---|---|---|---|
| Emitter long axis | 225 um | 200 um | Near-field emitting geometry only |
| Spectral FWHM | 5 nm | 7 nm | Excelitas has the narrower nominal value for narrowband filtering |
| Wavelength temperature slope | 0.25 nm/°C | 0.28 nm/K | A 40 °C change gives first-order estimates of about 10 nm and 11.2 nm |
| Parallel-junction divergence | 10° typical | 9° typical, 10° maximum | Typical values are close before collimation |
| Perpendicular-junction divergence | 25° typical | 25° typical, 28° maximum | Collimated spot still depends on lens NA, focal length and alignment |
Keep the concepts separate: emitter size describes near-field geometry, divergence describes far-field angle, and target-plane spot diameter also depends on collimating or beam-expanding optics. The PLD's 200 um long axis being shorter than the Excelitas 225 um does not prove a smaller spot or longer range.
Drive and thermal design: similar current, different voltage budget
Both devices are high-current, short-pulse loads. The driver cannot be selected from 75 W alone; current, voltage, edge rate, loop inductance, duty cycle and case temperature all matter.
| Drive item | Excelitas LTPGAU1S09 | PLD905-75W-M | Impact |
|---|---|---|---|
| Typical voltage at 30 A | 12.8 V | 16.8 V | Instantaneous electrical input during the pulse is about 384 W and 504 W |
| Peak current | 30 A listed limit | 30 A typical, 32 A absolute maximum | The driver needs adequate current and current limiting |
| Maximum duty cycle | 0.1% | 0.1% | 100 ns at 1 kHz is 0.01%; 100 ns at 3 kHz is 0.03% |
| Thermal load | 1 kHz test-table condition | 3 kHz standard condition | Higher repetition rate raises average heat at the same peak current |
| Cold boundary | -55 °C | -40 °C | Excelitas can be investigated for lower ambient temperature |
The instantaneous electrical input is a pulse operating-point estimate, not average power and not laser optical output. Driver design should follow measured device voltage, current and pulse shape, with voltage margin, low parasitic inductance and reverse protection.
Package and pinout: similar TO size is not drop-in compatibility


| Package item | Excelitas LTPGAU1S09 | PLD905-75W-M |
|---|---|---|
| Package class | 5.6 mm hermetic metal TO | TO56 metal package |
| Pinout | 1 Anode / 2 NC / 3 Cathode | Base M: 1 NC / 2 Cathode / 3 Anode |
| Other versions | The exact part in this comparison is LTPGAU1S09 | M, M/Z, M-2.0, MP |
| Pitch and pin style | Follow the three-pin drawing | Three-pin, 2.0 mm two-pin, 2.54 mm two-pin and others |
Before replacement, verify the bottom view, polarity, pitch, emitter-centre offset, flange dimensions, can height, PCB footprint and driver polarity. TO56 or 5.6 mm naming alone does not establish compatibility.
Application fit: shared 905 nm ranging foundation
| Application | Excelitas LTPGAU1S09 | PLD905-75W-M | System validation focus |
|---|---|---|---|
| LiDAR | Explicitly listed; C30737 epi-APD ecosystem referenced | Professional laser sensors and ranging listed | Receiver response, aperture, filter bandwidth, saturation, timing and thermal drift |
| Handheld ranging / LRF | Laser range finding listed | Handheld LRF, golf, hunting and civil engineering listed | Target reflectance, range, eye safety, ambient light and optomechanics |
| Drone ranging / obstacle avoidance | Can be assessed through LiDAR and ranging fit | Explicitly listed | Vibration, thermal cycling, window contamination, scanning, weight and power |
| Speed enforcement | Laser-based speed enforcement listed | Not separately listed | Repetition rate, timing accuracy, receive chain and regulatory certification |
| IR illumination | IR-illumination listed | Not separately listed | Uniformity, beam shaping, peak/average power and exposure safety |
| Excelitas APD matching | C30737 epi-APD family referenced | No matched detector model supplied | Spectral response, sensitivity, bias and timing interface require verification |
Neither datasheet provides a directly comparable maximum range, accuracy, target-reflectance matrix or complete-product eye-safety class. The 75 W peak figure alone cannot establish which part reaches farther.
Selection guidance: system constraints come before wattage
| Priority | Evaluate first | Further confirmation |
|---|---|---|
| Cold operating limit near -55 °C | LTPGAU1S09 | Cold start, low-temperature optical power, wavelength drift and long-term reliability |
| 5 nm spectral width and lower wavelength temperature coefficient | LTPGAU1S09 | Filter bandwidth, temperature sweep and batch spectra |
| Existing Excelitas C30737 epi-APD receive chain | LTPGAU1S09 | Spectral match, sensitivity, bias and timing |
| 5.6 mm hermetic metal TO structure | LTPGAU1S09 | Pinout, optical datum, mechanical dimensions and current availability |
| 100 ns, 3 kHz and 30 A validation point | PLD905-75W-M | Voltage margin, loop inductance, thermal design and waveform |
| Three-pin, 2.0 mm or 2.54 mm variants | PLD905-75W-M | Complete suffix, pinout, footprint and polarity |
| Drone, handheld LRF or professional distance-sensor direction | PLD905-75W-M | Airborne or portable environment, receiver dynamic range and safety |
The Excelitas document is a Preliminary Data Sheet revised in 2018-06. Confirm the current revision, production status and guaranteed parameters before purchase. PLD typical values may also change by batch and technology revision; obtain formal guarantees and test reports before production.
Suggested fair-comparison process
| Step | Test | Key records |
|---|---|---|
| 1. Align drive | 100 ns pulses at both 1 kHz and 3 kHz, identical current sweep and edge rate | Pulse waveform, peak current, voltage, overshoot and repeatability |
| 2. Align optics | Identical fixture, collimator, aperture, power/energy meter and beam profiler | Near field, far field, spectrum and pulse energy |
| 3. Align environment | Thermal steady state at -40, 25, 70 and 85 °C | Wavelength, peak power, threshold and repeatability |
Pulse-energy and average-power estimate
Using 75 W peak, 100 ns, 3 kHz and a rectangular pulse approximation:
| Item | Estimate | Relationship |
|---|---|---|
| Pulse energy | 7.50 uJ | E = Ppeak x tpulse |
| Average optical power | 22.50 mW | Pavg = E x frep |
| Duty cycle | 0.0300% | D = tpulse x frep |
| Pulse period | 333.3 us | T = 1 / frep |
Real pulse energy should be integrated from the measured optical waveform. If the FWHM definition, pulse shape or measurement bandwidth differs, correct the calculation to the datasheet basis and measured waveform. Continue with the peak-power calculator, average-power calculator and duty-cycle calculator.
What these two datasheets cannot establish
| Item | Reason |
|---|---|
| Which part reaches farther or is more accurate | No same-condition complete-system measurement or receiver comparison |
| Which die has longer life, higher yield or lower cost | No same-condition life, failure-rate or cost data |
| Which beam always creates a smaller target spot | Emitter, divergence, collimation and assembly all contribute |
| Which part holds identical power and wavelength at every temperature | No complete temperature curves or population data |
| Which package can replace the other without PCB changes | Pinout, polarity, dimensions and optical datum differ |
Common engineering questions
Both are marked 75 W. Are they direct replacements? No. Voltage, current, duty cycle, test frequency, pinout and emitter position must be reviewed.
The PLD emitter is shorter. Is its spot always smaller? No. Target-plane spot also depends on fast/slow-axis collimation, beam expansion, focal length and assembly error.
Can PLD be used at 80 W? 80 W is the maximum field in the rated peak-output table. It is not a continuous guaranteed operating point for every part and environment; design to guaranteed conditions with current limiting.
Is 905 nm eye-safe? No invisible near-infrared wavelength should be treated as automatically safe. Complete the applicable IEC 60825-1 and other laser-product assessments for the final optics, pulse parameters and accessible emission.
Continue with the PLD905-75W-M product page, the original Chinese comparison page or the PLD905-75W-M datasheet PDF.
Products
Related products
TO56 package
PLD905-75W-M
75 W peak, 905 nm, uncollimated
Calculators
Calculate with this datasheet
Each calculator below opens with this part's datasheet numbers already filled in, in the units the fields ask for.
Pulse Peak Power
Instantaneous peak power from pulse energy and pulse width.
Peak power 75 W · Pulse energy 0.0075 mJ · Pulse width 100 ns Laser FundamentalsAverage Power
Continuous average power from repetition rate and energy per pulse.
Energy per pulse 0.0075 mJ · Repetition rate 10 kHz Pulses & EnergyDuty Cycle
Ratio of laser on-time to the full period.
Duty cycle 0.1 % · Pulse width 100 ns · Repetition rate 10 kHz · Repetition rate (Hz) 10000 Hz Ranging & LiDARLiDAR Far-Field Spot
Beam diameter at long range.
Ranging & LiDARLiDAR Link Budget
Estimate the optical power captured at the receiver.
Related reading
785 nm multimode homogenized-fiber laser: uniform illumination, total-station optics and validation limits
A practical guide to a 785 nm, 90 mW, 200/340 um homogenized-fiber laser, covering illumination uniformity, total-station auxiliary optics, power budgeting and measurement.
Optics905 nm Raman DTS: engineering implementation and validation report
A complete engineering route from a 905 nm pulsed pump and approximately 870/943 nm Raman channels through dual APDs, synchronous acquisition, differential-loss correction, temperature inversion, calibration and prototype validation.
Selection guide905 nm vs 1535 nm vs 1550 nm: choosing a wavelength for ranging and LiDAR
The wavelength decision sets your detector, your eye-safety class, your maximum usable energy and your weather performance. Here is how the three bands actually compare for ranging work.