Selection guide

LTPGAU1S09 vs PLD905-75W-M: choosing between two 75 W class 905 nm pulsed lasers

A datasheet-based comparison of Excelitas LTPGAU1S09 and PLD905-75W-M covering their three-layer structure, 75 W typical power, 1 kHz and 3 kHz conditions, 30 A drive, spectrum, thermal drift, TO56 pinout and application boundaries.

Updated 2026-11-27 · 11 min read


PLD905-75W-M and Excelitas LTPGAU1S09 are both positioned as 905 nm, 75 W class pulsed sources for ranging, use a three-layer emitter/cavity approach and come in 5.6 mm class metal TO packages. The main differences are test frequency, emitter length, electrical operating point, temperature specifications and package details.

Both datasheets quote a 75 W typical value, but the Excelitas table uses 100 ns and 1 kHz while the PLD standard condition is 100 ns, 3 kHz and 30 A. The two watt figures must not be treated as a complete same-condition result.

Main conclusion: Evaluate LTPGAU1S09 first when the system values the wider cold operating and storage range, lower wavelength temperature coefficient, 5 nm spectral width and the Excelitas C30737 epi-APD ecosystem. Evaluate PLD905-75W-M first when the validation plan uses 100 ns, 3 kHz and 30 A, multiple TO56 pin/pitch variants are useful, and drone or handheld ranging applications matter. Final selection still requires measurement with the same driver, optics and receive chain.

Executive summary: similar power class, different system priorities

ComparisonExcelitas LTPGAU1S09PLD905-75W-MEngineering consequence
Centre wavelength905 nm typical; 895-915 nm905 nm typical; 895-915 nmBoth match common 905 nm silicon-detector ranging systems
Typical peak power75 W; 70 W minimum75 W; 65 W minimum and 80 W maximumTypical values match, but test frequency and grading methods differ
Typical test condition100 ns, 1 kHz100 ns, 3 kHz, 30 A, 25 °CThermal load and output cannot be ranked from power alone
Emitter225 x 10 um200 x 10 umThe PLD long axis is about 11.1% shorter; system spot reduction is not implied
Spectral width FWHM5 nm typical7 nm typicalExcelitas is nominally narrower, but filter and drift validation remain necessary
Operating temperature-55 to +85 °C-40 to +85 °CExcelitas specifies the lower cold limit

These similarities and differences support initial screening, not direct conclusions about measured range, lifetime, production yield or complete-system cost.

Device overview

Excelitas LU-series 5.6 mm TO metal packaged laser diode
Excelitas LTPGAU1S09: three emitting cavities, 225 x 10 um emitter and a 5.6 mm hermetic metal TO package.
PLD905-75W-M in a TO56 metal package
PLD905-75W-M: three epitaxial stacked emitters, a 200 x 10 um emitter and a TO56 metal package.

Detailed specification comparison

ParameterExcelitas LTPGAU1S09PLD905-75W-MObjective interpretation
Device routeLU-series Multi-epi; three emitting stripes/cavitiesNanoscale stacked laser; three epitaxial stacked emittersBoth use a three-layer/cavity route; deeper epitaxial detail requires supplier clarification
Centre wavelength905 nm typical; 895-915 nm spectral envelope905 nm typical; 895-915 nmNominal ranges are close; match the filter bandwidth and operating temperature
Spectral width FWHM5 nm typical7 nm typicalExcelitas is nominally narrower; benefit depends on filter, drift and detector response
Peak optical power70 W minimum, 75 W typical; 100 ns, 1 kHz65 W minimum, 75 W typical, 80 W maximum; 100 ns, 3 kHz, 30 ATypical values match, but test and grading methods are not identical
Emitter225 x 10 um200 x 10 umThe PLD long axis is about 11.1% shorter; target-plane spot cannot be inferred
Divergence parallel to PN10° typical9° typical, 10° maximumTypical values are close; PLD gives an explicit maximum
Divergence perpendicular to PN25° typical25° typical, 28° maximumTypical values are close; batch spread still requires measurement
Typical threshold current1.75 A0.75 AA lower threshold does not establish higher system efficiency or reliability
Operating current30 A listed peak-drive limit25 A minimum, 30 A typical, 32 A maximumPLD gives a more complete operating range
Typical forward voltage12.8 V at 30 A, estimated from series resistance and bandgap16.8 V at 30 APLD requires a larger voltage budget and rechecking switching loss
Series resistance / bandgap voltage0.21 ohm / 6.5 V typicalNot listed in the supplied tablePLD internal equivalent resistance cannot be inferred
Wavelength temperature coefficient0.25 nm/°C typical0.28 nm/K typicalExcelitas is nominally lower; system temperature sweeps remain necessary
Operating temperature-55 to +85 °C-40 to +85 °CExcelitas extends lower; this does not mean constant performance over the range
Storage temperature-55 to +105 °C-40 to +100 °CExcelitas specifies a wider range; storage limits are not operating limits
Pulse width100 ns maximum rating100 ns maximum rating; 1-100 ns short-pulse applicabilityBoth share the 100 ns ceiling; shorter pulses require new drive and power validation
Maximum duty cycle0.1%0.1%Pulse width, rate, case temperature and long-term heat must all remain inside limits
Reverse-voltage rating6 V20 VDefinitions may differ; a larger number does not justify larger reverse transients
Package5.6 mm hermetic metal TO, three pinsTO56 metal package, several pin/pitch variantsSimilar outlines are not direct replacements
Package inductance5 nHNot listedMissing PLD data does not mean lower inductance; request or measure it

The Excelitas values come from the LTPGAU1S09 column of the LU-series Preliminary Data Sheet. Common series values are stated at 23 °C, and the electro-optical table uses 100 ns and 1 kHz. PLD data follows PLD905-75W-M V3.0 at 100 ns, 3 kHz, 30 A and 25 °C.

Optical behaviour: spectrum and emitter geometry differ

Excelitas LU-series spectral and far-field curves
Excelitas page 3: peak radiant intensity, spectral distribution and far-field distribution parallel and perpendicular to the junction.
PLD905-75W-M power, spectrum, far-field and near-field curves
PLD905-75W-M P-V-I curves, 905 nm spectrum, far-field divergence and near-field spot at 100 ns, 3 kHz and 25 °C.
Optical itemExcelitas LTPGAU1S09PLD905-75W-MEngineering interpretation
Emitter long axis225 um200 umNear-field emitting geometry only
Spectral FWHM5 nm7 nmExcelitas has the narrower nominal value for narrowband filtering
Wavelength temperature slope0.25 nm/°C0.28 nm/KA 40 °C change gives first-order estimates of about 10 nm and 11.2 nm
Parallel-junction divergence10° typical9° typical, 10° maximumTypical values are close before collimation
Perpendicular-junction divergence25° typical25° typical, 28° maximumCollimated spot still depends on lens NA, focal length and alignment

Keep the concepts separate: emitter size describes near-field geometry, divergence describes far-field angle, and target-plane spot diameter also depends on collimating or beam-expanding optics. The PLD's 200 um long axis being shorter than the Excelitas 225 um does not prove a smaller spot or longer range.

Drive and thermal design: similar current, different voltage budget

Both devices are high-current, short-pulse loads. The driver cannot be selected from 75 W alone; current, voltage, edge rate, loop inductance, duty cycle and case temperature all matter.

Drive itemExcelitas LTPGAU1S09PLD905-75W-MImpact
Typical voltage at 30 A12.8 V16.8 VInstantaneous electrical input during the pulse is about 384 W and 504 W
Peak current30 A listed limit30 A typical, 32 A absolute maximumThe driver needs adequate current and current limiting
Maximum duty cycle0.1%0.1%100 ns at 1 kHz is 0.01%; 100 ns at 3 kHz is 0.03%
Thermal load1 kHz test-table condition3 kHz standard conditionHigher repetition rate raises average heat at the same peak current
Cold boundary-55 °C-40 °CExcelitas can be investigated for lower ambient temperature

The instantaneous electrical input is a pulse operating-point estimate, not average power and not laser optical output. Driver design should follow measured device voltage, current and pulse shape, with voltage margin, low parasitic inductance and reverse protection.

Package and pinout: similar TO size is not drop-in compatibility

Excelitas LU-series 5.6 mm TO package and pinout drawing
Excelitas LU: Pin 1 = LD Anode (+), Pin 2 = NC, Pin 3 = LD Cathode (-); package inductance 5 nH.
PLD905-75W-M TO56 package drawings
PLD905-75W-M: base M version Pin 1 = NC, Pin 2 = Cathode, Pin 3 = Anode; M/Z, M-2.0 and MP variants are also available.
Package itemExcelitas LTPGAU1S09PLD905-75W-M
Package class5.6 mm hermetic metal TOTO56 metal package
Pinout1 Anode / 2 NC / 3 CathodeBase M: 1 NC / 2 Cathode / 3 Anode
Other versionsThe exact part in this comparison is LTPGAU1S09M, M/Z, M-2.0, MP
Pitch and pin styleFollow the three-pin drawingThree-pin, 2.0 mm two-pin, 2.54 mm two-pin and others

Before replacement, verify the bottom view, polarity, pitch, emitter-centre offset, flange dimensions, can height, PCB footprint and driver polarity. TO56 or 5.6 mm naming alone does not establish compatibility.

Application fit: shared 905 nm ranging foundation

ApplicationExcelitas LTPGAU1S09PLD905-75W-MSystem validation focus
LiDARExplicitly listed; C30737 epi-APD ecosystem referencedProfessional laser sensors and ranging listedReceiver response, aperture, filter bandwidth, saturation, timing and thermal drift
Handheld ranging / LRFLaser range finding listedHandheld LRF, golf, hunting and civil engineering listedTarget reflectance, range, eye safety, ambient light and optomechanics
Drone ranging / obstacle avoidanceCan be assessed through LiDAR and ranging fitExplicitly listedVibration, thermal cycling, window contamination, scanning, weight and power
Speed enforcementLaser-based speed enforcement listedNot separately listedRepetition rate, timing accuracy, receive chain and regulatory certification
IR illuminationIR-illumination listedNot separately listedUniformity, beam shaping, peak/average power and exposure safety
Excelitas APD matchingC30737 epi-APD family referencedNo matched detector model suppliedSpectral response, sensitivity, bias and timing interface require verification

Neither datasheet provides a directly comparable maximum range, accuracy, target-reflectance matrix or complete-product eye-safety class. The 75 W peak figure alone cannot establish which part reaches farther.

Selection guidance: system constraints come before wattage

PriorityEvaluate firstFurther confirmation
Cold operating limit near -55 °CLTPGAU1S09Cold start, low-temperature optical power, wavelength drift and long-term reliability
5 nm spectral width and lower wavelength temperature coefficientLTPGAU1S09Filter bandwidth, temperature sweep and batch spectra
Existing Excelitas C30737 epi-APD receive chainLTPGAU1S09Spectral match, sensitivity, bias and timing
5.6 mm hermetic metal TO structureLTPGAU1S09Pinout, optical datum, mechanical dimensions and current availability
100 ns, 3 kHz and 30 A validation pointPLD905-75W-MVoltage margin, loop inductance, thermal design and waveform
Three-pin, 2.0 mm or 2.54 mm variantsPLD905-75W-MComplete suffix, pinout, footprint and polarity
Drone, handheld LRF or professional distance-sensor directionPLD905-75W-MAirborne or portable environment, receiver dynamic range and safety

The Excelitas document is a Preliminary Data Sheet revised in 2018-06. Confirm the current revision, production status and guaranteed parameters before purchase. PLD typical values may also change by batch and technology revision; obtain formal guarantees and test reports before production.

Suggested fair-comparison process

StepTestKey records
1. Align drive100 ns pulses at both 1 kHz and 3 kHz, identical current sweep and edge ratePulse waveform, peak current, voltage, overshoot and repeatability
2. Align opticsIdentical fixture, collimator, aperture, power/energy meter and beam profilerNear field, far field, spectrum and pulse energy
3. Align environmentThermal steady state at -40, 25, 70 and 85 °CWavelength, peak power, threshold and repeatability

Pulse-energy and average-power estimate

Using 75 W peak, 100 ns, 3 kHz and a rectangular pulse approximation:

ItemEstimateRelationship
Pulse energy7.50 uJE = Ppeak x tpulse
Average optical power22.50 mWPavg = E x frep
Duty cycle0.0300%D = tpulse x frep
Pulse period333.3 usT = 1 / frep

Real pulse energy should be integrated from the measured optical waveform. If the FWHM definition, pulse shape or measurement bandwidth differs, correct the calculation to the datasheet basis and measured waveform. Continue with the peak-power calculator, average-power calculator and duty-cycle calculator.

What these two datasheets cannot establish

ItemReason
Which part reaches farther or is more accurateNo same-condition complete-system measurement or receiver comparison
Which die has longer life, higher yield or lower costNo same-condition life, failure-rate or cost data
Which beam always creates a smaller target spotEmitter, divergence, collimation and assembly all contribute
Which part holds identical power and wavelength at every temperatureNo complete temperature curves or population data
Which package can replace the other without PCB changesPinout, polarity, dimensions and optical datum differ

Common engineering questions

Both are marked 75 W. Are they direct replacements? No. Voltage, current, duty cycle, test frequency, pinout and emitter position must be reviewed.

The PLD emitter is shorter. Is its spot always smaller? No. Target-plane spot also depends on fast/slow-axis collimation, beam expansion, focal length and assembly error.

Can PLD be used at 80 W? 80 W is the maximum field in the rated peak-output table. It is not a continuous guaranteed operating point for every part and environment; design to guaranteed conditions with current limiting.

Is 905 nm eye-safe? No invisible near-infrared wavelength should be treated as automatically safe. Complete the applicable IEC 60825-1 and other laser-product assessments for the final optics, pulse parameters and accessible emission.

Continue with the PLD905-75W-M product page, the original Chinese comparison page or the PLD905-75W-M datasheet PDF.


Products

Related products


Calculators

Calculate with this datasheet

Each calculator below opens with this part's datasheet numbers already filled in, in the units the fields ask for.

Epulse [µJ] = Ppeak [W] × tpulse [ns] ÷ 1000
D [%] = tpulse [ns] × frep [kHz] ÷ 10,000
Laser Fundamentals

Pulse Peak Power

Instantaneous peak power from pulse energy and pulse width.

Peak power 75 W · Pulse energy 0.0075 mJ · Pulse width 100 ns
Laser Fundamentals

Average Power

Continuous average power from repetition rate and energy per pulse.

Energy per pulse 0.0075 mJ · Repetition rate 10 kHz
Pulses & Energy

Duty Cycle

Ratio of laser on-time to the full period.

Duty cycle 0.1 % · Pulse width 100 ns · Repetition rate 10 kHz · Repetition rate (Hz) 10000 Hz
Ranging & LiDAR

LiDAR Far-Field Spot

Beam diameter at long range.

Ranging & LiDAR

LiDAR Link Budget

Estimate the optical power captured at the receiver.


Related reading

Have a specification, not a part number?

Send us the requirement - range, target, size, budget - and an engineer will come back with parts and the trade-offs between them.

Ask an engineer