Selection guide

LTPGAU1S03 vs PLD905-25W-M: choosing between two 905 nm three-layer pulsed lasers

A datasheet-based comparison of Excelitas LTPGAU1S03 and PLD905-25W-M covering chip architecture, 24 W versus 29 W typical-power conditions, drive current, divergence, temperature, TO56 pinout, applications and qualification boundaries.

Updated 2026-11-26 · 14 min read


PLD905-25W-M and Excelitas LTPGAU1S03 are both 905 nm multi-layer pulsed laser diodes aimed at TOF ranging and LiDAR. The most important differences are not in wavelength, but in the repetition-rate conditions behind their typical power figures, the electrical operating point, temperature boundaries and the pin definitions of the 5.6 mm TO package.

This article follows the supplied Excelitas LU-series Preliminary Data Sheet, Rev. 2018-06, and the PLD905-25W-M V3.0 datasheet. Excelitas states a 24 W typical output at 100 ns and 1 kHz. PLD states a 29 W typical output at 100 ns and 3 kHz. The two figures cannot be treated as a complete same-condition A/B measurement.

Main conclusion: Both devices use a three-layer emitting structure and produce typical optical power in the roughly 24 W and 29 W range. LTPGAU1S03 offers a wider specified temperature range, more series-level thermal and package parameters, and continuity for existing Excelitas platforms. PLD905-25W-M offers a higher typical output, a defined operating point near 11 A and TO56 ordering variants including M, M-2.0, MP and M/Z. Their pin functions are ordered differently, so neither part is a blind drop-in replacement.

Executive summary: similar platform, different system trade-offs

ItemExcelitas LTPGAU1S03PLD905-25W-MEngineering consequence
Typical optical power24 W; 21 W minimum29 W; 23.9 W minimum and 32.8 W maximumThe PLD typical value is higher, but the test frequencies differ
Typical-power condition100 ns, 1 kHz, 10 A maximum peak forward current100 ns, 3 kHz, 11 A typical, 25 °CThermal load and output cannot be ranked from the watt figure alone
Emitting structureThree emitter stripes/cavitiesThree epitaxial stacked emittersBoth have three layers; terminology and process disclosure differ
Emitting area75 x 10 um70 x 10 umThe PLD lateral dimension is smaller, but that does not prove a smaller system spot
TemperatureOperating -55 to +85 °C; storage -55 to +105 °COperating -40 to +85 °C; storage -40 to +100 °CExcelitas specifies a wider cold and storage range
Pin order1 = Anode, 2 = NC, 3 = Cathode1 = open, 2 = Cathode, 3 = AnodeThe functions are reversed; replacement requires mechanical and polarity review

A fair comparison must fix pulse width, repetition rate, peak current, temperature, heat-sink base and measurement instrumentation. Typical data is suitable for screening, not for a strict efficiency, lifetime or ranging-distance ranking.

Chip architecture: three layers, different datasheet terminology

Excelitas LU-series metal TO packaged laser diode
Excelitas LTPGAU1S03: LU-series multi-epi cavity architecture, three emitter stripes/cavities and a 75 x 10 um emitting area.
PLD905-25W-M in a TO56 metal package
PLD905-25W-M: nanoscale stacked laser technology, three epitaxial stacked emitters and a 70 x 10 um emitting area.

Excelitas describes the LU series as multiple active lasing layers grown epitaxially on a single GaAs substrate, with up to four layers in the series. The LTPGAU1S03 parameter table explicitly lists three emitter stripes/cavities. The PLD product description uses the term nanoscale stack and lists three epitaxial stacked emitters, but the supplied document does not disclose the complete epitaxial cross-section, interlayer dimensions or interface materials.

Architecture itemExcelitas LTPGAU1S03PLD905-25W-MObjective interpretation
Number of emitting layers/cavitiesThree emitter stripes/cavitiesThree epitaxial stacked emittersThe count matches; the terms are not strictly identical
Emitting area75 x 10 um70 x 10 umThe PLD lateral dimension is smaller; it does not by itself predict the far-field spot
Process descriptionMultiple epitaxial active layers on one GaAs substrateNanoscale stacked laser technologyThe disclosure depth differs; the data cannot rank epitaxial quality or life
Active emitting layer 1Active emitting layer 2Active emitting layer 3Concept only; not either supplier's actual epitaxial cross-section
Figure 1 Conceptual three-layer emitting structure. Excelitas describes multiple epitaxial cavities, while PLD describes a nanoscale stack with three epitaxial stacked emitters. The diagram does not imply identical epitaxial processes.

Optical performance: power, wavelength and divergence

ParameterExcelitas LTPGAU1S03PLD905-25W-MComparison note
Centre wavelength905 nm typical; series range 895-915 nm905 nm typical; 895-915 nmBoth fit the same 905 nm receive chain
Spectral width FWHM5 nm typical7 nm typicalExcelitas is nominally narrower; narrowband filters still require temperature and batch validation
Wavelength temperature coefficient0.25 nm/°C0.28 nm/K, numerically equal to nm/°CThe Excelitas slope is about 10.7% lower, but system thermal testing is still required
Divergence parallel to PN junction10° at 50% peak intensity9° typical, 10° maximum, FWHMPLD's typical value is slightly lower; the measurement descriptions are not identical
Divergence perpendicular to PN junction25°25° typical, 28° maximumTypical values match; PLD also supplies a maximum
Typical optical power24 W; 21 W minimum29 W; 23.9 W minimum, 32.8 W maximumPLD's typical value is higher, but 1 kHz and 3 kHz conditions differ
0102030 W24 W29 WLTPGAU1S03PLD905-25W-M100 ns · 1 kHz · 10 A max100 ns · 3 kHz · 11 A typ
Figure 2 Typical optical power from each datasheet. This is visualisation only, not a same-condition performance difference: Excelitas uses 1 kHz while PLD uses 3 kHz.
Excelitas LTPGAU1S03 datasheet power, spectrum, far-field and package plots
Excelitas LU-series optical data including power versus current, spectrum and far-field distribution parallel and perpendicular to the junction. This is series data, not a dual-device test on the same bench.
PLD905-25W-M datasheet power, voltage, spectrum, far-field and near-field plots
PLD905-25W-M characteristics at 100 ns, 3 kHz and 25 °C, including power/current/voltage, spectrum, far-field divergence and near-field emission.

The 70 x 10 um and 75 x 10 um values are chip emitting-area or aperture dimensions, not the final far-field spot diameter. The system spot depends on fast- and slow-axis divergence, lens focal length, numerical aperture, assembly decenter and working distance.

Electrical drive: current and voltage structure

ParameterExcelitas LTPGAU1S03PLD905-25W-MEngineering impact
Typical/maximum peak current10 A maximum peak forward current11 A typical; 13 A maximum ratingPLD requires a higher current capability and a matched pulse loop
Typical forward voltage10.6 V at 10 A, table estimate9.4 V at 11 A; 8.8-10 V rangeVoltage alone does not define drive difficulty; current must be included
Typical threshold current0.75 A0.75 AIdentical
Maximum reverse voltage6 V20 VLimits differ, but reverse transients should still be avoided; a limit is not a recommended operating value
Maximum pulse width100 ns100 nsIdentical; duty cycle and thermal limits must also be met
Maximum duty cycle0.1%0.1%Do not raise average output by increasing repetition rate without checking heat
Typical series resistance0.41 ohmNot suppliedExcelitas data can be used for voltage-drop estimation; PLD requires measurement or supplier data
Package inductance5 nHNot suppliedMissing data does not mean zero or lower inductance

Both devices require pulsed constant-current drive with control of peak current, edges, reverse transients, parasitic inductance and repetition rate. Do not treat one model's driver board as a plug-and-play replacement for the other.

Temperature and reliability: Excelitas specifies a wider range

ItemExcelitas LTPGAU1S03 / LU seriesPLD905-25W-MInterpretation
Operating temperature-55 to +85 °C-40 to +85 °CExcelitas extends 15 °C lower; the upper limit matches
Storage temperature-55 to +105 °C-40 to +100 °CExcelitas specifies the wider range
Wavelength temperature coefficient0.25 nm/°C0.28 nm/KThe Excelitas nominal slope is about 10.7% lower
Optical-power temperature coefficient-0.4%/°C, series specificationNot suppliedThis does not show that PLD is more or less stable
Thermal resistanceRthJA = 160 K/W, series specificationNot suppliedPLD thermal measurement is required before comparison
Reliability dataMarked High reliability; recommends keeping chip temperature at or below room temperature for best long-term reliabilityNo lifetime hours or accelerated-aging curve suppliedDocumentation alone cannot rank lifetime; compare same-condition degradation and failure rates

The wider Excelitas temperature range and series-level thermal parameters can help cold-platform and early thermal-budget work. PLD has the same +85 °C upper operating limit but does not disclose thermal resistance or the optical-power temperature coefficient in the supplied data. Temperature sweeps, case-temperature data, wavelength drift and aging data should be requested before production.

Package and pinout: not a blind replacement

Excelitas LU-series 5.6 mm TO metal package dimensions and pinout
Excelitas LU: 5.6 mm hermetic metal package; Pin 1 = LD Anode, Pin 2 = NC, Pin 3 = LD Cathode; package inductance is listed as 5 nH.
PLD905-25W-M TO56 metal package dimensions and pinout
PLD905-25W-M: TO56 metal package; Pin 1 = open, Pin 2 = Cathode, Pin 3 = Anode; 2.0 mm and 2.54 mm ordering variants are also available.
Package itemExcelitas LTPGAU1S03PLD905-25W-M
Package class5.6 mm CD hermetic metal TOTO56 metal package
Pinout1 Anode / 2 NC / 3 Cathode1 open / 2 Cathode / 3 Anode
Other versionsThe exact model in this table is LTPGAU1S03M, M-2.0, MP, M/Z
Mechanical interchangeabilityVerify bottom view, polarity and optical centreThe TO56 / 5.6 mm name does not establish compatibility

Replacement warning: The pin functions are ordered differently. Even though both outlines are 5.6 mm / TO metal packages, the pin number, polarity, case connection, optical-centre height, mounting orientation and PCB footprint must all be rechecked.

Application fit: shared 905 nm ranging role

ApplicationExcelitas LTPGAU1S03PLD905-25W-MNote
Industrial LiDAR / robot rangingApplicable basisApplicable basisValidate range, reflectance, receiver and safety class
Handheld laser rangefinderLU series lists range findingExplicitly lists golf, hunting and civil-engineering rangingFinal range cannot be derived from peak power alone
Drone ranging / obstacle avoidanceLists LiDAR and range findingExplicitly lists drone applicationsAlso evaluate weight, vibration, supply peaks, thermal path and eye safety
IR illumination / surveillanceExplicitly listedNot separately listedA potential PLD direction, but beam and drive require validation
Laser-based speed enforcementExplicitly listedNot separately listedValidate repetition rate and speed algorithm
High-volume commercial / consumer electronicsLU series is aimed at high volumeTO56 is suitable for volume applicationsCompare lead time, batch consistency and total cost
Test, measurement and researchExplicitly listedNot separately listedPLD curves can support system matching
Laser skin therapyListed in application listNot listedThe listing does not establish medical certification or direct medical use

An application list is not a complete system certification and does not guarantee a particular measured range. The complete transmitter, receiver, optics, algorithm and safety architecture still require joint validation.

Selection guidance: start with system constraints

PriorityEvaluate firstReason and caution
Existing Excelitas LU-series package, optics or driver interfaceLTPGAU1S03Stronger platform continuity; the supplied document is Preliminary and current production status must be checked
-55 °C operation or a wider storage range is mandatoryLTPGAU1S03Specified operating -55 to +85 °C and storage -55 to +105 °C
Series resistance, package inductance, thermal resistance and power temperature coefficient are neededLTPGAU1S03Series data gives 0.41 ohm, 5 nH, 160 K/W and -0.4%/°C references
A higher typical peak optical power is being evaluatedPLD905-25W-MTypical 29 W and minimum 23.9 W; remeasure across the 1 kHz and 3 kHz conditions
The driver can supply about 11 A typical and 13 A maximum pulsesPLD905-25W-MDefined operating point and multiple TO56 pinout variants
Handheld ranging and drone avoidance are target applicationsPLD905-25W-MStill validate system thermal behaviour, safety, receiver dynamic range and ambient light

Four qualification steps before selection

StepRequired workOutput
1. Align test conditionsFix pulse width, frequency, peak current, temperature, heat-sink base and instrumentationComparable power, pulse energy and waveform
2. Confirm the receive chainCheck 905 nm responsivity, filter bandwidth, field of view, noise and dynamic rangeSystem SNR and range budget
3. Verify the package interfaceCheck pinout, polarity, bottom view, height, optical centre and PCB footprintManufacturable optomechanical and driver interface
4. Run temperature and life testsMeasure temperature rise, power decay, wavelength drift and batch spread at maximum duty cycleDerating boundary and production criteria

The Excelitas document is a Preliminary Data Sheet revised in 2018. Obtain the current formal datasheet, PCN/EOL status and quality agreement before release. PLD parameters should follow the current controlled V3.0 or later datasheet.

Data boundaries and items to confirm

ItemWhy it mattersEvidence to request
Power and energy at the same frequencyExcelitas tabulates 1 kHz while the PLD standard curve is 3 kHzPower, energy and waveform reports at one pulse width, 1 kHz, 3 kHz and the target frequency
Power definition and measurement methodTypical, minimum and maximum definitions and instruments may differCalibrated power meter/integrating sphere or high-speed detector method and energy calibration
PLD thermal resistance and power temperature coefficientThe supplied PLD document does not provide themThermal resistance, base-temperature sweep, optical-power decay and wavelength drift
Current Excelitas availability and revisionThe supplied file is a Rev. 2018-06 Preliminary Data SheetCurrent formal datasheet, PCN/EOL status, quality agreement and volume commitment
Lifetime and reliabilityExcelitas mentions high reliability, but neither document supplies same-condition lifetime numbersPulsed lifetime, pre/post-aging power change, failure rate and failure analysis under one specification
Finished-product laser safetyBoth are invisible 905 nm near-infrared emittersComplete IEC 60825-1 and other applicable evaluations for the final optics, pulse settings and use case

905 nm is invisible near-infrared radiation and must not be treated as safe because it cannot be seen. The system requires beam protection, interlocks, labels, accidental-emission protection, test procedures and a final product laser-class assessment.

Datasheet sources and page index

Excelitas, High volume 5.6 mm TO metal package laser diode LU series, Preliminary Data Sheet LXPGAUYSZ, Rev. 2018-06: page 1 covers series architecture, features and applications; page 2 tables 1-3 cover absolute maximum ratings, common optical parameters and LTPGAU1S03-specific parameters; page 3 contains optical curves, package drawing, pinout and 5 nH package inductance; page 4 covers operating conditions, reliability and safety notes.

Leirte PLD905-25W-M V3.0: page 1 covers product description, model options, maximum ratings and optical parameters; page 2 covers current, voltage, emitting area, divergence and characteristic curves; pages 3-4 cover package outlines, pin definitions, terminology and safety notes.

This article does not fill undisclosed parameters with estimated values. Final procurement, replacement design and production release require the latest controlled supplier documents, sample measurements and written confirmation.

Continue with the PLD905-25W-M product page, the original Chinese comparison page or the PLD905-25W-M datasheet PDF.


Products

Related products


Calculators

Calculate with this datasheet

Each calculator below opens with this part's datasheet numbers already filled in, in the units the fields ask for.

Epulse [µJ] = Ppeak [W] × tpulse [ns] ÷ 1000
D [%] = tpulse [ns] × frep [kHz] ÷ 10,000
Laser Fundamentals

Pulse Peak Power

Instantaneous peak power from pulse energy and pulse width.

Peak power 25 W · Pulse energy 0.0025 mJ · Pulse width 100 ns
Laser Fundamentals

Average Power

Continuous average power from repetition rate and energy per pulse.

Energy per pulse 0.0025 mJ · Repetition rate 10 kHz
Pulses & Energy

Duty Cycle

Ratio of laser on-time to the full period.

Duty cycle 0.1 % · Pulse width 100 ns · Repetition rate 10 kHz · Repetition rate (Hz) 10000 Hz
Ranging & LiDAR

LiDAR Far-Field Spot

Beam diameter at long range.

Ranging & LiDAR

LiDAR Link Budget

Estimate the optical power captured at the receiver.


Related reading

Have a specification, not a part number?

Send us the requirement - range, target, size, budget - and an engineer will come back with parts and the trade-offs between them.

Ask an engineer