PLD905-25W-M and Excelitas LTPGAU1S03 are both 905 nm multi-layer pulsed laser diodes aimed at TOF ranging and LiDAR. The most important differences are not in wavelength, but in the repetition-rate conditions behind their typical power figures, the electrical operating point, temperature boundaries and the pin definitions of the 5.6 mm TO package.
This article follows the supplied Excelitas LU-series Preliminary Data Sheet, Rev. 2018-06, and the PLD905-25W-M V3.0 datasheet. Excelitas states a 24 W typical output at 100 ns and 1 kHz. PLD states a 29 W typical output at 100 ns and 3 kHz. The two figures cannot be treated as a complete same-condition A/B measurement.
Main conclusion: Both devices use a three-layer emitting structure and produce typical optical power in the roughly 24 W and 29 W range. LTPGAU1S03 offers a wider specified temperature range, more series-level thermal and package parameters, and continuity for existing Excelitas platforms. PLD905-25W-M offers a higher typical output, a defined operating point near 11 A and TO56 ordering variants including M, M-2.0, MP and M/Z. Their pin functions are ordered differently, so neither part is a blind drop-in replacement.
Executive summary: similar platform, different system trade-offs
| Item | Excelitas LTPGAU1S03 | PLD905-25W-M | Engineering consequence |
|---|---|---|---|
| Typical optical power | 24 W; 21 W minimum | 29 W; 23.9 W minimum and 32.8 W maximum | The PLD typical value is higher, but the test frequencies differ |
| Typical-power condition | 100 ns, 1 kHz, 10 A maximum peak forward current | 100 ns, 3 kHz, 11 A typical, 25 °C | Thermal load and output cannot be ranked from the watt figure alone |
| Emitting structure | Three emitter stripes/cavities | Three epitaxial stacked emitters | Both have three layers; terminology and process disclosure differ |
| Emitting area | 75 x 10 um | 70 x 10 um | The PLD lateral dimension is smaller, but that does not prove a smaller system spot |
| Temperature | Operating -55 to +85 °C; storage -55 to +105 °C | Operating -40 to +85 °C; storage -40 to +100 °C | Excelitas specifies a wider cold and storage range |
| Pin order | 1 = Anode, 2 = NC, 3 = Cathode | 1 = open, 2 = Cathode, 3 = Anode | The functions are reversed; replacement requires mechanical and polarity review |
A fair comparison must fix pulse width, repetition rate, peak current, temperature, heat-sink base and measurement instrumentation. Typical data is suitable for screening, not for a strict efficiency, lifetime or ranging-distance ranking.
Chip architecture: three layers, different datasheet terminology


Excelitas describes the LU series as multiple active lasing layers grown epitaxially on a single GaAs substrate, with up to four layers in the series. The LTPGAU1S03 parameter table explicitly lists three emitter stripes/cavities. The PLD product description uses the term nanoscale stack and lists three epitaxial stacked emitters, but the supplied document does not disclose the complete epitaxial cross-section, interlayer dimensions or interface materials.
| Architecture item | Excelitas LTPGAU1S03 | PLD905-25W-M | Objective interpretation |
|---|---|---|---|
| Number of emitting layers/cavities | Three emitter stripes/cavities | Three epitaxial stacked emitters | The count matches; the terms are not strictly identical |
| Emitting area | 75 x 10 um | 70 x 10 um | The PLD lateral dimension is smaller; it does not by itself predict the far-field spot |
| Process description | Multiple epitaxial active layers on one GaAs substrate | Nanoscale stacked laser technology | The disclosure depth differs; the data cannot rank epitaxial quality or life |
Optical performance: power, wavelength and divergence
| Parameter | Excelitas LTPGAU1S03 | PLD905-25W-M | Comparison note |
|---|---|---|---|
| Centre wavelength | 905 nm typical; series range 895-915 nm | 905 nm typical; 895-915 nm | Both fit the same 905 nm receive chain |
| Spectral width FWHM | 5 nm typical | 7 nm typical | Excelitas is nominally narrower; narrowband filters still require temperature and batch validation |
| Wavelength temperature coefficient | 0.25 nm/°C | 0.28 nm/K, numerically equal to nm/°C | The Excelitas slope is about 10.7% lower, but system thermal testing is still required |
| Divergence parallel to PN junction | 10° at 50% peak intensity | 9° typical, 10° maximum, FWHM | PLD's typical value is slightly lower; the measurement descriptions are not identical |
| Divergence perpendicular to PN junction | 25° | 25° typical, 28° maximum | Typical values match; PLD also supplies a maximum |
| Typical optical power | 24 W; 21 W minimum | 29 W; 23.9 W minimum, 32.8 W maximum | PLD's typical value is higher, but 1 kHz and 3 kHz conditions differ |


The 70 x 10 um and 75 x 10 um values are chip emitting-area or aperture dimensions, not the final far-field spot diameter. The system spot depends on fast- and slow-axis divergence, lens focal length, numerical aperture, assembly decenter and working distance.
Electrical drive: current and voltage structure
| Parameter | Excelitas LTPGAU1S03 | PLD905-25W-M | Engineering impact |
|---|---|---|---|
| Typical/maximum peak current | 10 A maximum peak forward current | 11 A typical; 13 A maximum rating | PLD requires a higher current capability and a matched pulse loop |
| Typical forward voltage | 10.6 V at 10 A, table estimate | 9.4 V at 11 A; 8.8-10 V range | Voltage alone does not define drive difficulty; current must be included |
| Typical threshold current | 0.75 A | 0.75 A | Identical |
| Maximum reverse voltage | 6 V | 20 V | Limits differ, but reverse transients should still be avoided; a limit is not a recommended operating value |
| Maximum pulse width | 100 ns | 100 ns | Identical; duty cycle and thermal limits must also be met |
| Maximum duty cycle | 0.1% | 0.1% | Do not raise average output by increasing repetition rate without checking heat |
| Typical series resistance | 0.41 ohm | Not supplied | Excelitas data can be used for voltage-drop estimation; PLD requires measurement or supplier data |
| Package inductance | 5 nH | Not supplied | Missing data does not mean zero or lower inductance |
Both devices require pulsed constant-current drive with control of peak current, edges, reverse transients, parasitic inductance and repetition rate. Do not treat one model's driver board as a plug-and-play replacement for the other.
Temperature and reliability: Excelitas specifies a wider range
| Item | Excelitas LTPGAU1S03 / LU series | PLD905-25W-M | Interpretation |
|---|---|---|---|
| Operating temperature | -55 to +85 °C | -40 to +85 °C | Excelitas extends 15 °C lower; the upper limit matches |
| Storage temperature | -55 to +105 °C | -40 to +100 °C | Excelitas specifies the wider range |
| Wavelength temperature coefficient | 0.25 nm/°C | 0.28 nm/K | The Excelitas nominal slope is about 10.7% lower |
| Optical-power temperature coefficient | -0.4%/°C, series specification | Not supplied | This does not show that PLD is more or less stable |
| Thermal resistance | RthJA = 160 K/W, series specification | Not supplied | PLD thermal measurement is required before comparison |
| Reliability data | Marked High reliability; recommends keeping chip temperature at or below room temperature for best long-term reliability | No lifetime hours or accelerated-aging curve supplied | Documentation alone cannot rank lifetime; compare same-condition degradation and failure rates |
The wider Excelitas temperature range and series-level thermal parameters can help cold-platform and early thermal-budget work. PLD has the same +85 °C upper operating limit but does not disclose thermal resistance or the optical-power temperature coefficient in the supplied data. Temperature sweeps, case-temperature data, wavelength drift and aging data should be requested before production.
Package and pinout: not a blind replacement


| Package item | Excelitas LTPGAU1S03 | PLD905-25W-M |
|---|---|---|
| Package class | 5.6 mm CD hermetic metal TO | TO56 metal package |
| Pinout | 1 Anode / 2 NC / 3 Cathode | 1 open / 2 Cathode / 3 Anode |
| Other versions | The exact model in this table is LTPGAU1S03 | M, M-2.0, MP, M/Z |
| Mechanical interchangeability | Verify bottom view, polarity and optical centre | The TO56 / 5.6 mm name does not establish compatibility |
Replacement warning: The pin functions are ordered differently. Even though both outlines are 5.6 mm / TO metal packages, the pin number, polarity, case connection, optical-centre height, mounting orientation and PCB footprint must all be rechecked.
Application fit: shared 905 nm ranging role
| Application | Excelitas LTPGAU1S03 | PLD905-25W-M | Note |
|---|---|---|---|
| Industrial LiDAR / robot ranging | Applicable basis | Applicable basis | Validate range, reflectance, receiver and safety class |
| Handheld laser rangefinder | LU series lists range finding | Explicitly lists golf, hunting and civil-engineering ranging | Final range cannot be derived from peak power alone |
| Drone ranging / obstacle avoidance | Lists LiDAR and range finding | Explicitly lists drone applications | Also evaluate weight, vibration, supply peaks, thermal path and eye safety |
| IR illumination / surveillance | Explicitly listed | Not separately listed | A potential PLD direction, but beam and drive require validation |
| Laser-based speed enforcement | Explicitly listed | Not separately listed | Validate repetition rate and speed algorithm |
| High-volume commercial / consumer electronics | LU series is aimed at high volume | TO56 is suitable for volume applications | Compare lead time, batch consistency and total cost |
| Test, measurement and research | Explicitly listed | Not separately listed | PLD curves can support system matching |
| Laser skin therapy | Listed in application list | Not listed | The listing does not establish medical certification or direct medical use |
An application list is not a complete system certification and does not guarantee a particular measured range. The complete transmitter, receiver, optics, algorithm and safety architecture still require joint validation.
Selection guidance: start with system constraints
| Priority | Evaluate first | Reason and caution |
|---|---|---|
| Existing Excelitas LU-series package, optics or driver interface | LTPGAU1S03 | Stronger platform continuity; the supplied document is Preliminary and current production status must be checked |
| -55 °C operation or a wider storage range is mandatory | LTPGAU1S03 | Specified operating -55 to +85 °C and storage -55 to +105 °C |
| Series resistance, package inductance, thermal resistance and power temperature coefficient are needed | LTPGAU1S03 | Series data gives 0.41 ohm, 5 nH, 160 K/W and -0.4%/°C references |
| A higher typical peak optical power is being evaluated | PLD905-25W-M | Typical 29 W and minimum 23.9 W; remeasure across the 1 kHz and 3 kHz conditions |
| The driver can supply about 11 A typical and 13 A maximum pulses | PLD905-25W-M | Defined operating point and multiple TO56 pinout variants |
| Handheld ranging and drone avoidance are target applications | PLD905-25W-M | Still validate system thermal behaviour, safety, receiver dynamic range and ambient light |
Four qualification steps before selection
| Step | Required work | Output |
|---|---|---|
| 1. Align test conditions | Fix pulse width, frequency, peak current, temperature, heat-sink base and instrumentation | Comparable power, pulse energy and waveform |
| 2. Confirm the receive chain | Check 905 nm responsivity, filter bandwidth, field of view, noise and dynamic range | System SNR and range budget |
| 3. Verify the package interface | Check pinout, polarity, bottom view, height, optical centre and PCB footprint | Manufacturable optomechanical and driver interface |
| 4. Run temperature and life tests | Measure temperature rise, power decay, wavelength drift and batch spread at maximum duty cycle | Derating boundary and production criteria |
The Excelitas document is a Preliminary Data Sheet revised in 2018. Obtain the current formal datasheet, PCN/EOL status and quality agreement before release. PLD parameters should follow the current controlled V3.0 or later datasheet.
Data boundaries and items to confirm
| Item | Why it matters | Evidence to request |
|---|---|---|
| Power and energy at the same frequency | Excelitas tabulates 1 kHz while the PLD standard curve is 3 kHz | Power, energy and waveform reports at one pulse width, 1 kHz, 3 kHz and the target frequency |
| Power definition and measurement method | Typical, minimum and maximum definitions and instruments may differ | Calibrated power meter/integrating sphere or high-speed detector method and energy calibration |
| PLD thermal resistance and power temperature coefficient | The supplied PLD document does not provide them | Thermal resistance, base-temperature sweep, optical-power decay and wavelength drift |
| Current Excelitas availability and revision | The supplied file is a Rev. 2018-06 Preliminary Data Sheet | Current formal datasheet, PCN/EOL status, quality agreement and volume commitment |
| Lifetime and reliability | Excelitas mentions high reliability, but neither document supplies same-condition lifetime numbers | Pulsed lifetime, pre/post-aging power change, failure rate and failure analysis under one specification |
| Finished-product laser safety | Both are invisible 905 nm near-infrared emitters | Complete IEC 60825-1 and other applicable evaluations for the final optics, pulse settings and use case |
905 nm is invisible near-infrared radiation and must not be treated as safe because it cannot be seen. The system requires beam protection, interlocks, labels, accidental-emission protection, test procedures and a final product laser-class assessment.
Datasheet sources and page index
Excelitas, High volume 5.6 mm TO metal package laser diode LU series, Preliminary Data Sheet LXPGAUYSZ, Rev. 2018-06: page 1 covers series architecture, features and applications; page 2 tables 1-3 cover absolute maximum ratings, common optical parameters and LTPGAU1S03-specific parameters; page 3 contains optical curves, package drawing, pinout and 5 nH package inductance; page 4 covers operating conditions, reliability and safety notes.
Leirte PLD905-25W-M V3.0: page 1 covers product description, model options, maximum ratings and optical parameters; page 2 covers current, voltage, emitting area, divergence and characteristic curves; pages 3-4 cover package outlines, pin definitions, terminology and safety notes.
This article does not fill undisclosed parameters with estimated values. Final procurement, replacement design and production release require the latest controlled supplier documents, sample measurements and written confirmation.
Continue with the PLD905-25W-M product page, the original Chinese comparison page or the PLD905-25W-M datasheet PDF.
Products
Related products
TO56 package
PLD905-25W-M
25 W peak, 905 nm, uncollimated
Calculators
Calculate with this datasheet
Each calculator below opens with this part's datasheet numbers already filled in, in the units the fields ask for.
Pulse Peak Power
Instantaneous peak power from pulse energy and pulse width.
Peak power 25 W · Pulse energy 0.0025 mJ · Pulse width 100 ns Laser FundamentalsAverage Power
Continuous average power from repetition rate and energy per pulse.
Energy per pulse 0.0025 mJ · Repetition rate 10 kHz Pulses & EnergyDuty Cycle
Ratio of laser on-time to the full period.
Duty cycle 0.1 % · Pulse width 100 ns · Repetition rate 10 kHz · Repetition rate (Hz) 10000 Hz Ranging & LiDARLiDAR Far-Field Spot
Beam diameter at long range.
Ranging & LiDARLiDAR Link Budget
Estimate the optical power captured at the receiver.
Related reading
785 nm multimode homogenized-fiber laser: uniform illumination, total-station optics and validation limits
A practical guide to a 785 nm, 90 mW, 200/340 um homogenized-fiber laser, covering illumination uniformity, total-station auxiliary optics, power budgeting and measurement.
Optics905 nm Raman DTS: engineering implementation and validation report
A complete engineering route from a 905 nm pulsed pump and approximately 870/943 nm Raman channels through dual APDs, synchronous acquisition, differential-loss correction, temperature inversion, calibration and prototype validation.
Selection guide905 nm vs 1535 nm vs 1550 nm: choosing a wavelength for ranging and LiDAR
The wavelength decision sets your detector, your eye-safety class, your maximum usable energy and your weather performance. Here is how the three bands actually compare for ranging work.