Laser Selector
Result summary
| Item | Value | Unit | Notes |
|---|
Formula
Limits and assumptions
Engineering estimate based on the formula above. Verify selected parts against the current datasheet and system tolerances before production.
Fiber & Lasers
Marcuse approximation of the mode field diameter 2w of a step-index fiber.
Every number is read from that part's datasheet entry and converted into the unit the field asks for.
Core radius a = 4.5 μm; V-number = 2.405 ; Numerical aperture NA = 0.14 ; Wavelength = 1550 nm
Drawn from the values above, redrawn as you type - the same physical schematic the mini-program shows.
The link reopens the same solve target and input values. No account is required.
The report includes inputs, units, result, formula, limits and matching parts.
PDF opens the print dialog; choose Save as PDF.
Both codes reach the same engineer. Scan with the phone camera, or use the button below.