Pulse definition
The base formula assumes a rectangular pulse. FWHM is not the same as the energy-equivalent duration; convert it first or apply the shape factor shown above.
-
Ratings are coupled
Peak power cannot be raised by shortening a pulse without considering current, duty cycle, junction heating and the diode's safe operating area. The PLD905 standard family quotes 1–100 ns pulses and 0.1% maximum duty cycle; confirm the exact model and bin.
-
Duty-cycle check
Duty = τ × f_rep. At 100 ns, a 0.1% limit caps repetition rate at 10 kHz. Average power is P_avg = E × f_rep; verify it separately against the thermal budget.
-
Energy is operating-point dependent
Datasheet pulse energy is usually stated at a defined current, width and temperature. Do not assume that peak power or energy scales linearly outside that point.
-
Optical measurement
Driver rise time, ringing, overshoot, optical losses and detector bandwidth all change the measured result. Use a calibrated optical waveform and integrate energy over the full pulse.
-
Laser safety
Peak power, average power, wavelength and pulse duration all enter the laser-safety assessment. Keep the system inside its declared laser class and applicable standards.